8.2
Power
HART
Nominal 24 V DC at 550 Ohm. For other configurations, refer the chart under "Loop power" in
the full operating instructions.
PROFIBUS PA and FOUNDATION FIELDBUS
Bus powered
Current consumed
8.3
Construction
Process connection:
Enclosure
Lens antenna
material
Air purge connection
Weight (excluding
extensions):
Universal flange mates with EN 1092-1 (PN16)/ASME B16.5 (150 lb)/JIS 2220 (10K) bolt hole pat-
1)
tern.
SITRANS LR560
Compact Operating Instructions, 02/2022, A5E39693895-AC
9 to 32 V DC, per IEC 61158-2
13.5 mA
Universal flat-faced flange
Aimer flange
1)
Universal stamped
flange
1)
Construction
Conduit entry
Conduit entry connector
(optional)
Ingress protection
Lid with window
Sun shield (optional)
40 m version
100 m version
equipped with female 1/8" NPT fitting
3" stainless steel flange
model
3"/80 mm, 4"/100 mm, 6"/150 mm
1)
Material: 316L (1.4404 or 1.4435), or 304
stainless steel
3"/80 mm, 4"/100 mm, 6"/150 mm
Material: Polyurethane powder-coated cast
aluminum
3"/80 mm, 4"/100 mm, 6"/150 mm
Material: 304 stainless steel
316L/1.4404 stainless steel
M20x1.5, or ½" NPT
M12 connector (shipped with M20 to M12
adaptor) or,
7/8" connector (shipped with 1/2" NPT to 7/8"
adaptor)
Type 4X, Type 6, IP68
Polycarbonate (window material)
304 stainless steel
PEI
PEEK
3.15 kg (6.94 lb)
Technical data
8.2 Power
53