Download Print this page

Assa Abloy Pando S559685084 Quick Start Manual page 2

Secure reader

Advertisement

Available languages

Available languages

About Pando Secure
Pando Secure reader will continue to be referred as Pando Secure
or reader in this document.
Pando Secure is a Hi-O reader with the opportunity to be
able to communicate through Hi-O or the old CL protocol.
Hi-O should be used primarily if both sockets are available in
LCU or DAC.
By default the Pando Secure reads serial number on the
cards but the reader can be configured for sector reading of
MIFARE Classic, applications reading of MIFARE DESFire,
iCLASS or SEOS. All configuration are made with a
customer specific Setup card.
Installation
Hi-O devices are easy to install, all devices are connected in
parallel and just using four wires. Units on the Hi-O bus gets
its supply voltage from the DAC 530, DAC564 or LCU9101.
DIP- switch 1-8.
DIP function
1
Address value 1
2
Address value 2
3
CL mode: Address value 4
Hi-O mode
OFF= in reader
ON= out reader
4
Key beep, beep when keystrokes and major &
minor signal at invalid / valid card.
5
Card beep, Beep at card read
6
Selection Hi-O/CL (OFF = CL, ON = Hi-O)
7
Light ON, Keypad always lit.
8
Light Code, Keypad lit when the indication for
door code/PIN code is activated.
And a delay on 0.5 seconds will be activated for
the A and B keys to avoid unwanted maneuvers.
QR to technical support
IS559685940F
Information
Pando Secure is a combine Hi-O and CL readers
Pando Secure can when in Hi-O mode be connected to the Hi-O
DAC500, DAC530, and DAC564. In CL mode it can work with
DAC420, DAC430 and DAC44. When connected to a LCU it can
work as an elevator reader.
Hi-O installation
Connect the CAN bus to CAN-H and CAN-L
Connect the power to terminals, +12 V & 0V in the DAC/LCU.
Indications Hi-O Mode DIP6 = ON
Green: lights when the reader is uninitialized at the Hi-O bus. Pando
reader is not locked to a specific Hi-O bus.
Red: lights when the reader is locked to a specific Hi-O bus,
indicating that the reader is locked and encrypted to the bus.
Indications CL mode DIP6 = OFF
Green: TX, activity, via CL-20
Red: RX, activity, via CL-20
Delayed reactions at A and B keys
To delay the A and B key to avoid unwanted maneuvers set the
DIP 8 to ON.
Note! This switch also activates the backlight when the PIN LED are
lit. (Function is v
alid from firmware version 1.05.30)
Configuration of sector reading
Turn the power of and on to the reader by detach and
1.
attach the "plug able" terminal.
Green indication flashes for 90 seconds.
2.
Before it stops flashing, show the Setup card to the
3.
reader
The reader indicates that the programming is finished
4.
with a "chirp" and the green indication is unlit.
The reader is now programmed with the encryption keys
5.
of the site.
Note! If a card presented to a Pando Secure reader doesn't have
encryption keys corresponding with the reader the reader will not
indicate that anything is wrong and the reader will not send any
data.
Technical specifications
Part number
S559685084 S559685N084
Power supply
12-24V DC (min
10.8V, max 27,6V DC)
Power Consumption
12V: 80mA, Max 96mA. 24V: 40mA, Max 48mA (Max 1,15W)
Recommended cable
EKKX 2x2x0,2
Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with a rated output
current limited to ≤2 A.
Hi-O cable length
Totalt:
Grenledning:
Temperature
– 25°C to + 55°C (– 13°F to + 131°F)
Below -25°C, – 13°F, the reader must be heated externally.
Humidity
5 % to 95 %
IP
54
Max mounting height
2m above floor
Dimensions
H 157 mm, W 56 mm, D 22 mm.
Storage and transport
Temperature: -50 ºC to 70 ºC (-58 ºF to 158 ºF)
Humidity 5 % to 95 %
Terminal
Can-H
CAN-H
Connection to the Hi-O bus (DIP6 = ON)
Can-L
CAN-L
+V
+ V (12-24 DC)
Power to the reader, through a fused unit as LCU9101,
0V
0V
C+
CL+
Connection to the CL bus (DIP6 = OFF)
C-
CL-
DAC420, DAC430, DAC44, and a elevator reader to the LCU.
NC
Free
Addressing CL MODE
Address DIP1
DIP2
DIP3
0
OFF
OFF
OFF
In reader DAC430 Standard
1
ON
OFF
OFF
Extra In reader for DAC430
(Used when the two in readers desired)
2
OFF
ON
OFF
3
ON
ON
OFF
4
OFF
OFF
ON
Out reader DAC430 Standard
(Group in/out reader for Hi-O mode when DIP6 = ON)
5
ON
OFF
ON
Extra Out reader for DAC430
(Used when the two out readers desired)
6
OFF
ON
ON
7
ON
ON
ON
Reset of Hi-O locked reader
1.
Turn Off and On the power to the reader.
A red LED is lit, indicating that the reader is locked
2.
Within 10 seconds. Turn DIP 3 ON and OFF with one second's interval, 6-8 times
3.
The reader switches to green LED after reboot or directly
4.
The reader is now Hi-O unlocked, and can be moved to another door
Max. 50 m
Max. 10 m
DAC500, DAC530, DAC564
DAC530 or DAC564.
Address space not for used
Address space not for used

Advertisement