Immergas NIKE Mini 24 Export Manual page 39

Compact instantaneous wall-hung conventional flue boilers, compact wall-hung conventional flue boilers for central heating only
Table of Contents

Advertisement

Technical Documentation
NIKE Mini 28 technical data.
Nominal heat input
Minimum heat input
Nominal heat output (useful)
Minimum heat output (useful)
Efficiency at 100%
Efficiency at 30% of load
Outer casing losses with burner On/Off
Stack losses with burner On/Off
Gas nozzle diameter
Supply pressure
Max. central heating circuit pressure
Maximum heating temperature
C.H. temperature adjustment
C.H. total expansion vessel volume
C.H. expansion vessel preload pressure
Appliance water content
Available head with 1000 l/h flow rate
D.H.W. useful thermal power
D.H.W. temperature adjustment
D.H.W. flow limiter
Min. pressure for nominal flow rate
Minimum dynamic pressure d.h.w. circuit
Max. d.h.w. circuit pressure
Minimum flow rate for d.h.w.
Flow rate for continuous service (∆T 30°C)
Specific flow rate (∆T 30°C)
Boiler weight full
Boiler weight empty
Electrical connection
Nominal power draw
Electric power installed
Circulator power draw
Electrical insulation degree
Fumes flow rate at max heat output
Fumes flow rate at min heat output
CO
at Q. Nom./Min.
2
CO at 0% of O
at Q. Nom./Min.
2
NO
at 0% of O
at Q. Nom./Min.
X
2
Exhaust flue temperature at max heat output
Exhaust flue temperature at min heat output
Boiler flue circuit resistance
NO
class
X
NO
weighted
X
CO weighted
Type of appliance
Category
- The flue temperature values refer to an air inlet temperature
of 15°C.
- Data relative to d.h.w. performance refer to a dynamic inlet
pressure of 2 bar and an inlet temperature of 15°C; these
values are measured at boiler outlet considering that to find
these declared values mixing with cold water is necessary.
STNM ed 07/07
Technical Documentation
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
%
%
%
%
mm
mbar (mm H
O)
20 (204)
2
bar
°C
°C
l
bar
l
kPa (m H
O)
2
kW (kcal/h)
°C
l/min
bar
bar
bar
l/min
l/min
l/min
kg
kg
V/Hz
A
W
W
-
kg/h
kg/h
%
5.5 / 2.4
ppm
ppm
378 / 235
°C
°C
Pa
-
mg/kWh
mg/kWh
37
30.6 (26286)
12.0 (10321)
27.6 (23736)
10.5 (9000)
90.3
89.1
3.3 / 1.08
6.4 / 0.25
G20
G30
1.30
0.78
29 (296)
37 (377)
3
90
38 - 85
4.5
1.0
2.9
22.55 (2.30)
27.6 (23736)
30 - 60
9.3
1.5
0.3
10
≤ 2.0
12.8
13.2
33.9
31
230/50
0.42
95
81
IPX4D
G20
G30
78
75
67
67
6.7 / 2.8
6.4 / 2.8
68 / 95
97 / 150
58 / 130
481 / 141
426 / 134
96
101
65
66
1.3
3
128
45
B11BS
III1a2H3+
NIKE Mini Export
G31
0.78
G31
77
67
98
66

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nike mini 28 exportNike mini 24 s exportEolo mini 24 exportEolo mini 28 exportEolo mini 24 s export

Table of Contents