Waiting time. The boiler has an electronic timer that prevents
too frequent burner ignitions in the central heating mode.
The boiler has its own standard timer set at 3 minutes.
Central heating ignitions timer
Range of settable values
from 1 to 10
3 = 3 minutes (Standard setting)
1 = 30 seconds
Central heating ignition ramp timer. The boiler carries out
an approximate 10 minute ignition ramp to go from minimum
power to nominal central heating power.
Central heating ramp timer
Range of settable values
from 1 to 10
10 = 10 minutes (Standard setting)
1 = 30 seconds
Boiler type. By selecting this parameter you can choose the
mode for the type of boiler in use: instant single-heating boiler
(0), dual-heating boiler (1) or single-heating boiler with stor-
age tank (2) (in the case of combining NIKE Mini 24 S with a
separate storage tank).
NOTE: depending on the selection made, also move the JP1
jumper on the p.c.b.: position 1-2 for the bithermal boiler or
position 2-3 for the mono-thermal boiler.
Attention: the boiler is factory set so only use this function if
the electronic board is replaced.
Boiler type
Range of settable values
from 0 to 2
0 = mono-thermal boiler (instantaneous)
1 = bithermal boiler
2 = mono-thermal boiler (with storage tank)
STNM ed 07/07
Parameter
P7
Parameter
P8
Parameter
P9
34