Carefully inspect the suction element, with
reference to the surface highlighted in yellow,
ensure that scratches or dents on the inner
surface of the element, may affect the ability of
soliciting or impair the performance of the pump,
if not cause the rapid destruction , due to the
contact with the impeller, in the case in which it
has been replaced with a new one.
In that case, replace the suction element.
24) To remove the external magnet, unscrew the
locking socket screw.
Now you can replace all worn or damaged parts.

Pump reassembling

To reassemble the pump, follow the instructions in reverse order.
Thoroughly clean every component before assembly, make sure all parts are free of dirt, metal particles, etc.
ISM0210
Instruction Manual of series SCE- Rev.03
23) Repeat what described from the point 19 to 22,
for each stage in this construction (1 to 8 stages).
32) With the aid of an extractor, extract the external
magnet.
Pag. 23/33