M Pumps SCE Series User Manual

M Pumps SCE Series User Manual

Magnetic drive pumps centrifugal, horizonthal, top-top, side channel, metallic
Table of Contents

Advertisement

Quick Links

M PUMPS PROCESS SRL
Via dell'artigianato, 120
Setting I nnovative
45015 Corbola (RO) – Italia
Standards
Tel. +39 0426 346304 Fax + 39 0426 349126
info@mpumps.it
MAGNETIC DRIVE PUMPS
Centrifugal, Horizonthal, Top-Top,
Side Channel, Metallic
• SCE series
User Manual
This copy of the manual is a translation of the Italian version
and both manuals must be always furnished together
MODEL: pump only
MODEL: pump and motor assembly (Close Coupled version)
CAUTION
These instructions are intended for operators:
- Pump installation by qualified personnel;
- Use the pump, by staff
- Carry out maintenance / repair of the pump.
Read this instruction manual before using the pump.
ISM0034 CT MAG-MS series instruction manual. Issue of 2012 rev.03- do not destroy, do not modify

Advertisement

Table of Contents
loading

Summary of Contents for M Pumps SCE Series

  • Page 1 M PUMPS PROCESS SRL Via dell’artigianato, 120 Setting I nnovative 45015 Corbola (RO) – Italia Standards Tel. +39 0426 346304 Fax + 39 0426 349126 info@mpumps.it MAGNETIC DRIVE PUMPS Centrifugal, Horizonthal, Top-Top, Side Channel, Metallic • SCE series User Manual...
  • Page 2 THIS INSTRUCTION MANUAL is intended to guide those responsible for the installation, operation and maintenance of M PUMPS PROCESS SCE series seal-less magnetic drive pumps. Please read it carefully, before you install and operate your M PUMPS PROCESS pump. Useful information can also be obtained from: - Hydraulic Institute Standards (USA) regarding pump installation.
  • Page 3: Table Of Contents

    CONTENTS GENERAL WARNINGS AND SAFETY ............................. 4 Symbols used in the manual ................................. 4 WARRANTY ..................................4 NAMEPLATE ..................................5 Key feature of magnetic drive pumps is that the fluid that have to be moved never comes into direct contact with engine parts, ensuring the physical separation between the motor and the pump and the transmission is delivered via a coaxial magnetic coupling.
  • Page 4: General Warnings And Safety

    This reflects the state of the art at the marketing pump. In case of transfer of the pump, the user is encouraged to report to M PUMPS PROCESS the address of the new owner to facilitate the transmission of any additions to the manual to the new user.
  • Page 5: Nameplate

    − the repair and / or maintenance was not carried out strictly in accordance with the instructions; − the pump has not been installed and put into service as instructed; − the repairs were not made by staff M PUMPS PROCESS or were made without consulting M PUMPS PROCESS;...
  • Page 6 The serial number of the pump, here called serial number (s.nr) defines the type of components installed in the pump: Pag. 6/33 ISM0210 Instruction Manual of series SCE - Rev.03...
  • Page 7: Key Feature Of Magnetic Drive Pumps Is That The Fluid That Have To Be Moved Never Comes Into Direct Contact With

    PUMP DESCRIPTION AND OPERATING PRINCIPLE OF SIDE CHANNEL PUMPS 2. Key feature of magnetic drive pumps is that the fluid that have to be moved never comes into direct contact with engine parts, ensuring the physical separation between the motor and the pump and the transmission is delivered via a coaxial magnetic coupling.
  • Page 8: Applications

    ITEM DESCRIPTION Discharge Stage Outlet Mini channel Secondary gas discharge Suction Stage Inlet Impeller Equalization Holes Applications − pumps in general, this model is ideal for clean liquids slightly contaminated, no particles that may become magnetized; − the maximum working pressure of the plant,the temperature suitable and the maximum rotation speed depends type pump...
  • Page 9: Technical Data

    TECHNICAL DATA The pumps described in this manual have the following characteristics: Available in bare shaft configuration or close couple, with the engine directly keyed to the pump support. • Nozzle: DIN PN16 flanged; • Max viscosity: 200 cps; • Max system pressure: 16 BAR (standard) •...
  • Page 10 Pag. 10/33 ISM0210 Instruction Manual of series SCE - Rev.03...
  • Page 11: Noise And Vibration

    The pump does not emit any kind of ionising radiation that could endanger persons. CHECKS TO PUMP DELIVERY, STORAGE M PUMPS PROCESS pumps are tested before shipment and carefully packed for transport: at the reception of the pump make sure that the pump has not been damaged during the transport. If there are problems, contact...
  • Page 12: Assembly, Installation, Connections, Commissioning And Setting

    Ensure that the heated air from other units does not affect the pump; the air temperature must not exceed M PUMPS PROCESS 40 °C, for higher temperatures contact your distributor ; ensure also the free circulation of air cooling of at least ¼...
  • Page 13: Checks For The Proper Operation

    Fully open the inlet valve and fill the pump and suction line; − − Ensure there are no obstacles to the free rotation of the pump impeller. M PUMPS PROCESS series SCE are not reversible so the rotation ROTATION SENSE: cannot be reversed.
  • Page 14: Self-Priming Pumps And Non Self-Priming Pumps

    “TECHNICAL DATA” are followed. Instructions for proper use reasonably foreseeable Before starting work you must check that: M PUMPS − All maintenance actions were properly carried out according to the time intervals set by − There are no damaged parts of the pump;...
  • Page 15: Residual Risks And Protection Measures To Be Taken

    It is incorrect any use of the pump other than that mentioned in the paragraph “Instructions for a proper use reasonably foreseeable”. M PUMPS PROCESS disclaims any liability damages to things and people related to uses for which the pump was not specifically designed and constructed.
  • Page 16: Safety Information Present On The Pump

    After shocks accidentally suffered by the pump, check the pump integrity and perform a check to − M PUMPS PROCESS − After a long period of pump detention check the pump integrity and functionality of stakeholders to wear. If necessary perform the replacement with identical spare parts to the originals.
  • Page 17: Fire-Fighting Equipment To Be Used

    Reduce the total head of the system if possible. Increase the diameter of the discharge pipe. Check that the discharge valve is fully open. Replace the pump. M PUMPS PROCESS distributor. Ask your Check the direction of rotation. The pump rotates in the opposite direction.
  • Page 18 Reduce the prevalence of the pump (check in advance with your distributor M PUMPS PROCESS ). Make sure the pump turns freely; inspect the inside in case this does not happen. Reduce the...
  • Page 19 Replace the motor bearings, investigate the causes of The motor bearings are damaged or worn breakage. Motor under dimensioned Mount a more powerful motor (check in advance with your M PUMPS PROCESS distributor Check Motor overload threshold set incorrectly the security settings of the motor...
  • Page 20: Periodic And Extraordinary Maintenance

    Ball bearings or motor failure. Check and replace them if necessary. Make sure that the motor and base plate are firmly anchored to foundations and do not produce any Uninsured motor or base plate abnormal vibration. Check correct alignment of pipes and supports, refer to Misalignment or improper anchoring of the pipes.
  • Page 21: Emptying Of The Fluid Contained In The Pump

    If it becomes necessary to disassemble the pump, you must remember that the liquid should be collected and disposed in accordance to existing environmental laws. If the pump should be sent to M PUMPS PROCESS it must be drained, and should not contain any traces of liquid pumped.
  • Page 22 18) Remove the rear sleeve shaft and replace it in case of wear or damage. 19) Remove the pressing element of the side channel stage. Carefully inspect pressing element, with reference to the surface highlighted in yellow, ensure that scratches or dents on the inner surface of the element, may affect the ability of soliciting or impair the performance of the pump, if not cause the rapid destruction , due to the contact with the...
  • Page 23: Pump Reassembling

    Carefully inspect the suction element, with reference to the surface highlighted in yellow, ensure that scratches or dents on the inner surface of the element, may affect the ability of soliciting or impair the performance of the pump, if not cause the rapid destruction , due to the contact with the impeller, in the case in which it has been replaced with a new one.
  • Page 24: Decommissioning, Dismantling And Disposal Of Materials

    CAUTION A good stocking will guarantee against unpleasant incidents during the restarting of the pump. M PUMPS PROCESS disclaims any responsibility for machines stored incorrectly. If you intend to stop using this pump it is recommended to make it inoperative.
  • Page 25: Exploded View Part List

    EXPLODED VIEW PART LIST Close coupled version ISM0210 Instruction Manual of series SCE- Rev.03 Pag. 25/33...
  • Page 26 Pag. 26/33 ISM0210 Instruction Manual of series SCE - Rev.03...
  • Page 27: Notes

    NOTES ISM0210 Instruction Manual of series SCE- Rev.03 Pag. 27/33...
  • Page 28: Appendix A - Register Of Maintenance And Periodic Checks Of The Pump

    APPENDIX A – Register of maintenance and periodic checks of the pump It is provided a list of maintenances to be carried out and their respective ranges; you must register these operations. Commissioning date: ____________________ Main maintenance operations to be performed by the second year of use onwards: Warnings and protective measures Required check be taken to perform maintenance...
  • Page 29: Appendix B - Startup Check List

    APPENDIX B – Startup check list PERIPHERAL REGENERATIVE, SIDE CHANNEL & VOLUMETRIC PUMP SERIES Rev. N°00 - Do not destroying – do not modify - Date 21/02/2013 This document consists STARTUP CHECK LIST of 2 pages NO / YES / Description of activity ...
  • Page 30 electrical personnel? Have the Pump Bearings been filled with recommended Lubricating Oil and to the stated level (For Long Coupled Pump)? Have the motor Bearings been greased if required? * PRE START-UP For High /Low Temperature Pumping application , has the pump been warmed up to required Temperature? Can the Pump shaft turns freely by hand? Fully Open the Suction Valve.
  • Page 31 Under Normal Condition, continuously run the pump under observation for one or two hours. COMMENTS/REMARKS: INSTALLATION REFERENCE: CONTACT: PROJECT: CONTRACTOR: ADDRESS: FAX: PHONE NO: SERIAL NR: PUMP MODEL NO: IMPELLER MOTOR TYPE: DIAMETER: FOLLOW UP START-UP BY: REQD: DATE: SIGNATURE: Please send this document, duly completed, to the e-mail: info@mpumps.it, or by FAX at: +39 0426 349126 ISM0210...
  • Page 32 M PUMPS PROCESS S.R.L. Sede Legale: Via Milite Ignoto, 51 – 45019 – Taglio di Po – (RO) – Italy Sede operativa: Via dell’Artigianato, 120 - 45015 Corbola (RO) – Italy Tel.: +39 0426 346304 Fax: +39 0426 349126 E-mail: info@mpumps.it ISM0210 Instruction Manual of series SCE- Rev.03...

Table of Contents