M Pumps SCE Series User Manual page 19

Magnetic drive pumps centrifugal, horizonthal, top-top, side channel, metallic
Table of Contents

Advertisement

The head required is lower than that
provided by the pump
OVERHEATING OR MOTOR STOP
Excessive pumped liquid density
The pump has seized or is about to seize
The motor and pump are misaligned
The motor bearings are damaged or worn
Motor under dimensioned
Motor overload threshold set incorrectly
The guard against the motor dry running
(where present) has failed or has been set
.
incorrectly
FUNCTIONING WITH NOISE DEFECTS AND/OR
VIBRATIONS
Causes
Insufficient inlet pressure, consequent
cavitation, insufficient lubrication of the
bearings (with mechanical damages if the
condition persists).
STOP IMMEDIATELY THE PUMP!
Wear, erosion and immediate damage to the
impeller and internal bearings.
Wear of the coupling motor-pump
Reduce the speed of rotation, if possible; reduce the impeller
diameter; partially close the discharge valve.
Reduce the flow by closing the valve outlet partially
.
Check the free rotation of the impeller. Check for internal
obstructions
Refer to section 3.8 of this manual
.
Replace the motor bearings, investigate the causes of
breakage.
Mount a more powerful motor (check in advance with your
distributor
Check
Control flow decreases or fluid intake
Remedies / actions
Refer to paragraphs 3.4, 3.5, 4.1, 4.2, 4.3 of this manual
Check inside the pump damages or obstructions.
Replace the coupling and proceed to the realignment of
pump and motor.
ISM0210
Instruction Manual of series SCE- Rev.03
.
M PUMPS PROCESS
the security settings of the motor
).
.
Pag. 19/33

Advertisement

Table of Contents
loading

Table of Contents