40" 80% and 90% gas furnaces and accessories
Table of Contents

Advertisement

PRODUCT DESIGN
UPRIGHT INSTALLATIONS
In an upright installation drain hoses are connected to drain
ports on the rubber elbow and the recouperator coil front
cover. The drain lines are then routed through the right or left
side panel and into the drain trap secured to the outside of
the cabinet.
NOTE: Refer to Condensate Drain Lines and Drain Trap -
Alternate Vent/Flue Hose Connections section in this
manual or the installation instructions for upright installa-
tions using an alternate vent/flue outlet.
Standard Right or Left Side Drain Hose Connections
Upright installations using the standard vent/flue outlet re-
quire drain hoses to be connected as shown in the following
figures.
NOTE: For left side drainage, grommets will have to be
relocated to left side panel.
RED HOSE
FRONT COVER
CLAMP
DRAIN PORT
90% Furnace Upright "Standard"
Drain Hose Connections (Right Side)
LEFT
SIDE PANEL
FRONT COVER
DRAIN PORT
RED HOSE
CLAMP
HOSE A
SIDE PANEL
GROMMET
HOLES
TUBE(S) 2
DRAIN
TRAP
90% Furnace Upright "Standard"
Drain Hose Connections (Left Side)
NOTE: Ensure hoses and tubes maintain a downward slope
for proper drainage and that they are not kinked or binding.
54
Rev. 1
RIGHT SIDE
PANEL
RUBBER
ELBOW
RUBBER ELBOW
DRAIN PORT
RED HOSE CLAMP
TUBE 1
HOSE
SIDE PANEL
B
GROMMET
HOLES
TUBE(S) 2
HOSE
DRAIN
A
GREEN
TRAP
HOSE
CLAMPS
(3 PLACES)
RUBBER
ELBOW
RUBBER
ELBOW
DRAIN PORT
RED HOSE
CLAMP
TUBE 1
GREEN HOSE
CLAMPS
(3 PLACES)
HOSE B
Alternate Vent/Flue Drain Hose Connections
Upright installations using the alternate vent/flue outlet will
require "right-side only" drain hoses to be connected as
shown in the following figure. Refer to Vent/Flue Pipe and
Combustion Air Pipe section in this manual or the installa-
tion instructions for details on alternate vent/flue pipe con-
nection.
HOSE A
FRONT COVER
DRAIN PORT
TUBE(S) 2
90% Furnace Upright "Alternate"
Drain Hose Connections (Right Side Only)
NOTE: Ensure hoses and tubes maintain a downward slope
for proper drainage and are not kinked or binding.
For details concerning mounting of the drain trap, refer to
the following section.
Upright Drain Trap Mounting (Left or Right Side Panel)
1. Insert drain tubes into drain trap and position the drain
trap against the side panel. NOTE: Drain tubes must
reach the bottom of the drain trap.
2. Secure drain trap to side panel at the mounting holes
located below the grommet drain holes.
3. Attach PVC drain line to drain trap outlet with either a
90° elbow or coupling.
NOTE: Ensure hoses and tubes maintain a downward slope
for proper drainage and that they are not kinked or binding.
RUBBER ELBOW
(EXTERNALLY
MOUNTED)
RUBBER
ELBOW
DRAIN PORT
TUBE 1
HOSE
CLAMPS
(5 PLACES)
HOSE B
SIDE PANEL
GROMMET
HOLES
DRAIN TRAP

Hide quick links: