STA-RITE MAX-E-THERM 77707-1341 Service Manual page 6

Pool heater fuel gas conversion kit natural gas to propane (lpg)
Table of Contents

Advertisement

Available languages

Available languages

BLOWER IDENTIFICATION NOTICE
IMPORTANT:
The orifices in this kit
are only used in the
blower on the RIGHT.
Sta-Rite
Pentair
Gas and Air Orifices are not interchangeable
between the two blower types.
Risk of fire or explosion
if this kit is incorrectly installed
or is installed on the wrong unit.
This kit must match your heater's fuel
type when service is complete
(Propane or Natural Gas),
its BTU rating (200K, 333K, or 400K),
and its blower type.
If any of these items do not match,
DO NOT INSTALL THE KIT.
Call 1-800-752-0183 to order
the correct kit for your unit.
If your blower
looks like the one on
the left, you MUST NOT
replace the orifices
with the ones in this kit.
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Max-e-therm 77707-1351Max-e-therm 77707-1361

Table of Contents