MAX-E-THERM
FUEL GAS CONVERSION KIT
NATURAL GAS TO PROPANE (LPG)
Kit No. 77707-1341 converts Models SR/SRC400NA and SR400HD to Propane (LPG)
Kit No. 77707-1351 converts Models SR/SRC333NA to Propane (LPG)
Kit No. 77707-1361 converts Models SR/SRC200NA to Propane (LPG)
NOTICE: See "Blower Identification Notice," Page 6
Failure to follow instructions could result in fire or explosion with
serious injury or property damage. This conversion kit shall be installed by
a qualified service agency in accordance with the manufacturer's instruc-
tions and all applicable codes and requirements of the authority having
jurisdiction. The information in these instructions must be followed to mini-
mize the risk of fire or explosion or to prevent property damage, personal
injury, or death. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in the manu-
facturer's instructions supplied with the kit.
IN CANADA: "THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS
OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIRE-
MENTS OF THE CAN-B149.1 AND CAN-B149.2 INSTALLATION CODE."
This kit is for the purpose of converting a Sta-Rite Max-E-Therm™ heater from natural gas to Propane
(LPG). It is not designed to alter the input to the appliance and must not be used to attempt to alter the
input from the original nameplate rating.
The term "qualified agency" means any individual, firm, corporation or company which either in person or through a
representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connec-
tion, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions
required, and has complied with all the requirements of the authority having jurisdiction. A Sta-Rite distributor with
service personnel trained to install or repair gas heaters is a qualified agency.
Sta-Rite Pool/Spa Group
293 Wright Street, Delavan, WI 53115
International: 262-728-5551, FAX: 262-728-7550
www.starite.com
Union City, TN • Delavan, WI • Mississauga, ON
© 2005, Sta-Rite Industries
S E R V I C E
INSTALLATION INSTRUCTIONS
POOL HEATER
M A N U A L
S630 (Rev. 11/30/05)

Advertisement

Table of Contents
loading

Summary of Contents for STA-RITE MAX-E-THERM 77707-1341

  • Page 1 MENTS OF THE CAN-B149.1 AND CAN-B149.2 INSTALLATION CODE.” This kit is for the purpose of converting a Sta-Rite Max-E-Therm™ heater from natural gas to Propane (LPG). It is not designed to alter the input to the appliance and must not be used to attempt to alter the input from the original nameplate rating.
  • Page 2: Safety Instructions

    3/4". needs must be made by a Sta-Rite dealer or other qualified Check for compliance with local codes. agency using factory specified and approved parts.
  • Page 3 Remove Connection for NOTICE: The gas piping and Test Orifice unions have been omitted for clarity; make this test with all To High Side Swing Gas Line gas piping connected (as for of Differential to One Side Pressure Gauge normal service). To Air Flow Switch Vent...
  • Page 4: High Altitude Installation

    12. Install a 1/8" NPT barbed fitting into the ‘PRESSURE Table 3: Flue Gas CO and O Ranges TAP’ port on the outlet side of the gas valve. Use a Recommended CO Recommended O flexible tube to connect it to the low side of a differen- tial pressure gauge or a slope gauge .
  • Page 5: Sequence Of Operation

    Model SR/SRC400....399,990BTU/Hr fied range. Sequence Of Operation Mixture Too Rich - (too much gas) For detailed information, please refer to Sta-Rite Pool/Spa Symptoms: Heater Training and Service Manual, publication no. A. CO too high or S5066.
  • Page 6 MUST NOT are only used in the replace the orifices blower on the RIGHT. with the ones in this kit. Sta-Rite Pentair Gas and Air Orifices are not interchangeable between the two blower types. Risk of fire or explosion if this kit is incorrectly installed or is installed on the wrong unit.
  • Page 7 à une telle intervention et elle doit se conformer à toutes les exigences de l’autorité ayant compétence. Un distributeur Sta-Rite ayant du personnel technique formé pour installer et réparer les chauffe-piscines/spas fonctionnant au gaz est une agence qualifiée.
  • Page 8: Instructions Pour L'installation

    Si l'appareil doit être converti d'un type de gaz à l'extérieur de l'enceinte du chauffe-piscine/spa. Ne pas poser à un autre, s'adresser à un concessionnaire Sta-Rite, sinon un très un robinet limitant le débit du gaz. mauvais fonctionnement du brûleur peut se produire, ce qui risque Il est recommandé...
  • Page 9 Branchement Nota : Pour que l’illustration soit plus Connection for Déposer NOTICE: pour procéder The gas piping and claire, les tuyaux et les raccords Test l’ajutage aux contrôles. unions have been omitted for unions pour le gaz ne sont pas illus- clarity;...
  • Page 10 12. Brancher un raccord cannelé de 1/8 de pouce NPT dans Tableau 3 : Plages de CO et d’O des gaz brûlés l’orifice «PRESSURE TAP» côté sortie de la soupape à gaz recommandé recommandé mixte. Brancher un tube souple sur le côté bas d’un Combustible (Base sèche) (Base sèche)
  • Page 11 Sta-Rite, n° de Remèdes : publication S5066. Appeler Sta-Rite pour obtenir un ajutage de propane plus petit de Une thermistance de détection de la température logée côté 5 %. arrivée de l’adaptateur de la tubulure contrôle le fonctionnement Répéter l’installation de l’ajutage en commençant à...
  • Page 12 être remplacé par celui être utilisé qu’avec la livré avec la trousse. soufflante de DROITE. Sta-Rite Pentair Les injecteurs d’air et de gaz ne sont pas interchangeables entre les deux types de soufflantes. Il peut y avoir risque d’incendie ou d’explosion si cette trousse n’est pas posée correctement...

This manual is also suitable for:

Max-e-therm 77707-1351Max-e-therm 77707-1361

Table of Contents