Pool heater fuel gas conversion kit natural gas to propane (lpg)
Table of Contents

Advertisement

Available languages

Available languages

NOTICE:
The gas piping and
unions have been omitted for
clarity; make this test with all
gas piping connected (as for
normal service).
To Air Flow
Switch
Figure 1: Vent valve tap connection to mixer inlet
NOTICE: Before converting the heater, make the necessary
gas connections to the new gas supply, following the
instructions in the heater owner's manual.
Verify the maximum and minimum regulated gas pressures
from the gas supply. These pressures must be within the
range listed on the conversion plate.
Conversion Procedure (NG to Propane)
1. Turn off the electrical supply to the heater; turn off the
pump; turn off the manual gas supply valve to the heater.
2. Unbolt and separate the top jacket halves (see Figure 2).
2585 0497
Figure 2: Separate Jacket Halves
3. Unscrew completely the 3/4" gas line union closest to
the combination gas control valve.
4. Loosen the 3/4" gas line union directly above the air
inlet tube.
5. Loosen the pipe clamp holding the gas line to the
upper control support and swing the gas line loop out
of the way (see Figure 3).
Connection for
Test
To High Side
of Differential
Pressure Gauge
Vent
Press
Tap
To Low Side of
Figure 3: Swing Gas Line Out of the Way.
Differential
Pressure Gauge
6. Remove the gas orifice and O-Ring contained in the
union nearest the combination gas control valve.
2788 0397
7. Install the O-Ring on the Propane conversion orifice.
Verify the correct size of the Propane orifice included
in your kit (see Table 2).
Table 2: Replacement Propane Orifice Size Code
Model
SR/SRC400
SR/SRC333
SR/SRC200
8. Insert the Propane orifice squarely in the gas line union
next to the combination gas valve (see Figure 4).
Figure 4: Install Orifice; Reconnect Unions.
9. Swing the gas loop and union half back into place
and tighten both unions securely.
10. Tighten the pipe clamp holding the gas line to the top
control support.
11. Use a 3/16" hex key to remove the plug from the
'PRESSURE TAP' port on the outlet side of the
Combination Gas Control Valve.
3
Swing Gas Line
to One Side
Air Inlet
Tube
Part No.
ID Stamp
42001-0341
42001-0351
42001-0361
Install O-Ring
Reconnect
Gas Line
2809 0497
Remove
Orifice
2801 0497
Size (")
D
.409
E
.340
F
.244
Install
Orifice

Advertisement

Table of Contents
loading

This manual is also suitable for:

Max-e-therm 77707-1351Max-e-therm 77707-1361

Table of Contents