PiezoDrive PDUS210 Manual And Specifications page 20

210 watt ultrasonic driver
Hide thumbs Also See for PDUS210:
Table of Contents

Advertisement

Current Tracking Switch - Enables and disables current tracking.
• The output voltage will be adjusted until the measured current equals the current setpoint.
• When enabled, the output voltage cannot be manually changed.
• Recommended when tracking a series resonance.
• Will disable power tracking
• The voltage will not be adjusted until the phase tracking is locked, i.e. there is less than 10
degrees difference between the measured phase and the phase set point.
Power Tracking Switch - Enables and disables power tracking.
• The output voltage will be adjusted until the measured load power equals the power set point.
• When enabled, the output voltage cannot be manually changed.
• Will disable current tracking
• The voltage will not be adjusted until the phase tracking is locked, i.e. there is less than 10
degrees difference between the measured phase and the phase set point.
Remote Amplitude Switch - Enables and disables the front panel amplitude control.
• When enabled, the remote dial will change the output voltage from zero to the maximum
amplitude.
• If current tracking is enabled, the dial will change the current set point from zero to the
maximum output current.
• If power tracking is enabled, the dial will change the power set point from zero to the
maximum load power.
Max Power - The maximum power that can be supplied to the
load, in Watts.
• If this maximum value is exceeded, an overload will be
triggered and the amplifier output will be disabled.
Max Voltage - The output voltage limit, in Volts RMS.
• Limits voltage when power or current tracking is enabled
Max Current - The maximum current that can be supplied to the
load, in Amps RMS.
• Limits current when power or current tracking is enabled
Transformer Turns - The transformer turns for the FLEX version.
Voltage - Sets the output voltage, in Volts RMS.
• Cannot be changed if power or current tracking is enabled
PDUS210 V5 Manual
20
Modified 17/12/2022

Advertisement

Table of Contents
loading