If Something Goes Wrong; Error Code - TESY AquaThermica Compact HPWH 3.2 100 User Manual

Domestic hot water heat pump
Hide thumbs Also See for AquaThermica Compact HPWH 3.2 100:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Antifreeze mode
Even when the appliance is in standby mode, if lower tank temp. ≤ 5°C, anti-frozen protection starts. The Heat pump is forced to
work.
When lower tank temp. ≥ 10°C, it exits Anti-frozen protection.
Symbol P06 is flashing on display, without icon "Error".
If both P06 and "Error" appear on display, see chapter "error codes"
Disinfection weekly cycle
The E-heater will start each week at the setting time automatically. (When the unit is off at constant temperature or at
standby mode, Anti-legionnaire function is on)
When upper water tank temp. ≥ 70°C, the heater stops. When upper water tank temp. ≤ 70°C-2°C, the heater starts.
It keeps the upper water tank temp in range (70°C-2°C) to 70°C for he set disinfection time 30mins, after 30mins, then quit
the disinfection. The timer will be cleared and start to next timer cycle.
E-heater Priority level: 1) defrost or anti-frozen; 2) disinfection; 3) other controls
Switch off the unit! Disconnect it the from main power supply!
Call to the service and inform them about the error code or describe all abnormalities and strange behavior
or noise of your appliance!
Error codes
During standby or running status, if there is a malfunction, the unit will stop automatically and show the error code on the screen of
the controller. Call to the service!
Error
Stand by
Normal running
Lower tank water temp. sensor failure
Upper tank water temp. sensor failure
Coil temp. sensor failure
Suction air temp sensor failure
Ambient temp. sensor failure
Winter Anti-frozen protection failure
High pressure protection (HP Switch)
This symbol on the product(s) and / or accompanying documents means that used electrical and electronic equipment
(WEEE) should not be mixed with general household waste. For proper treatment, recovery and recycling, please take
this product(s) to designated collection points where it will be accepted free of charge. Disposing of this product correctly
will help save valuable resources and prevent any potential negative effects on human health and the environment,
which could otherwise arise from inappropriate waste handling.

IF SOMETHING GOES WRONG!

ERROR CODE

7
Code
P01
P02
P03
P04
P05
P06
E01