Viking pump F-1020 Installation Operation & Maintenance

Viking pump F-1020 Installation Operation & Maintenance

Advertisement

VISIT VIKINGPUMP.COM FOR PDF OF CURRENT TSM ISSUE & TO VIEW REPAIR VIDEOS
TECHNICAL SERVICE MANUAL: INSTALLATION, OPERATION & MAINTENANCE
TABLE OF CONTENTS

Model Number Chart ..................................................................1

Introduction ................................................................................1

Special Information ....................................................................2
Installation ..................................................................................2
Disassembly ...............................................................................3
Assembly ....................................................................................3
O-Ring Information .....................................................................3
Troubleshooting .........................................................................4
FIGURE 1
PARTS & ACCESSORIES
BOLTED-LID SIMPLEX
IN-LINE BASKET-TYPE STRAINERS
MODEL NUMBER CHART
INTRODUCTION
The illustrations used in this manual are for identification
purposes only and cannot be used for ordering parts.
This bulletin deals exclusively with Viking Bolted-Lid Basket-
Type Strainers. When ordering parts be sure to give complete
part name, serial number and model number. The basket
mesh size is stamped on the basket handle and the O-Ring
construction can be identified with a Viking color code (listed
Bolts
under O-Ring Information).
Use of basket strainers can avoid costly failures and increase
Plug
the life of the equipment. Proper use of strainer can minimize
down time. A definition for strainers is "a coarse filter".
Lid
Strainers are typically intended to trap larger foreign objects
such as rags, weld beads or bolts. Filters are intended to
capture very small particles.
O-Ring
Lid sealing is accomplished with one O-Ring, therefore
proper application of O-Ring is essential. The O-Ring must
be acceptable for the temperature limits of the system as well
as compatible with the fluid being strained. Misapplication
Strainer Basket
may result in O-Ring swell (making lid removal difficult) or
premature O-Ring failure, causing strainer leakage.
Strainer Body
Plug
Plug
© 2019 Viking Pump, Inc. • Cedar Falls, IA
TSM
1987
Page
1 of 4
Issue
A
F-1020
F-1030
F-1040

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F-1020 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Viking pump F-1020

  • Page 1 Misapplication Strainer Basket may result in O-Ring swell (making lid removal difficult) or premature O-Ring failure, causing strainer leakage. Strainer Body Plug Plug © 2019 Viking Pump, Inc. • Cedar Falls, IA...
  • Page 2 ① System pressure ratings are for temperature range of 0°F to 150°F per ANSI B16.42 Ductile Iron pipe flanges and flanged fittings. TSM 1987 | Issue A | Page 2 of 4 © 2019 Viking Pump, Inc. • Cedar Falls, IA...
  • Page 3 Hot hydrofluoric or chlorosulfonic acids ① Temperatures listed are for static seal applications only for the Lid-Ease Simplex strainer line. ② Source: Parker O-Ring Handbook TSM 1987 | Issue A | Page 3 of 4 © 2019 Viking Pump, Inc. • Cedar Falls, IA...
  • Page 4 Viking through regular mail at Viking Pump, Inc., 406 State Generally it is best to have an extra O-Ring on hand when Street, Cedar Falls, Iowa 50613, USA.

This manual is also suitable for:

F-1030F-1040

Table of Contents