Coleman LX Series Technical Manual page 35

Split system heat pumps
Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
IDCFM
AIR TEMP.
ENTERING
ID DB (°F)
OUTDOOR UNIT (°F)
ID WB (°F)
55
65
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Green shaded cells are ACCA (TVA) conditions.
Blue shaded cells are AHRI conditions.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COIL MULTIPLIERS - 3 TON
Air Handler
Coil
AE36BX21
AE36CX21
AVC36BX21
AVC36CX21
ME12BN21
CF/CM36B
ME12CN21
CF/CM36C
ME16CN21
CF/CM36C
MVC12BN21
CF/CM36B
MVC12CN21
CF/CM36C
MVC16CN21
CF/CM36C
FURNACE MULTIPLIERS - 3 TON
Furnaces
Coil
TL8E080C16UH11
CF/CM/CU36C
TL8E100C20UH11
CF/CM/CU36C
TL9E100C20UH11
CF/CM/CU36C
TM8E080C16MP11
CF/CM/CU36C
TM8E080C20MP11
CF/CM/CU36C
TM8E100B12MP11
CF/CM/CU36B
TM8E100B12MP11
CF/CM/CU36C
Johnson Controls Ducted Systems
TE4B3621S
900
80
80
75
57
62
62
T.C.
31.8
34.6
34.5
S.C.
31.8
28.5
24.5
KW
1.94
1.93
1.93
T.C.
30.8
33.4
33.4
S.C.
30.8
28.3
23.9
KW
2.13
2.12
2.12
T.C.
29.8
32.2
32.2
S.C.
29.8
27.9
23.3
KW
2.35
2.35
2.35
T.C.
28.7
30.8
30.9
S.C.
28.7
27.4
22.7
KW
2.61
2.60
2.61
T.C.
27.6
29.3
29.3
S.C.
27.6
26.6
22.0
KW
2.90
2.90
2.90
T.C.
26.3
27.7
27.7
S.C.
26.3
25.7
21.3
KW
3.23
3.23
3.23
T.C.
25.0
26.0
25.8
S.C.
25.0
24.5
20.5
KW
3.59
3.59
3.59
T.C.
23.6
24.1
23.8
S.C.
23.6
23.2
19.6
KW
3.99
3.99
3.98
T.C.
S.C.
1.03
1.01
1.02
0.98
1.02
0.98
1.02
0.99
1.01
0.97
1.02
0.99
1.02
0.99
1.02
0.98
1.02
0.99
1.02
0.99
T.C.
S.C.
1.02
0.99
1.02
0.98
1.02
0.98
1.01
0.97
1.02
0.98
1.01
0.98
1.02
0.98
1200
80
80
80
80
75
67
72
57
62
62
37.2
39.6
34.0
36.0
35.7
24.4
19.1
34.0
31.7
26.8
1.92
1.92
2.03
2.03
2.03
36.4
39.1
33.2
34.8
34.6
24.0
18.8
33.2
31.9
26.4
2.12
2.12
2.23
2.23
2.23
35.3
38.3
32.2
33.5
33.4
23.5
18.4
32.2
31.4
25.9
2.35
2.35
2.45
2.45
2.45
34.0
37.2
31.1
32.1
32.0
23.0
18.0
31.1
30.4
25.4
2.61
2.61
2.72
2.71
2.72
32.5
35.8
29.8
30.6
30.4
22.4
17.6
29.8
29.3
24.7
2.91
2.91
3.01
3.01
3.01
30.8
34.1
28.4
29.0
28.7
21.7
17.0
28.4
28.0
24.0
3.24
3.24
3.34
3.34
3.34
28.8
32.0
26.9
27.4
26.7
20.8
16.3
26.9
26.6
23.1
3.59
3.60
3.70
3.70
3.69
26.7
29.7
25.3
25.6
24.6
19.8
15.5
25.3
25.1
22.0
3.99
3.99
4.10
4.10
4.09
FURNACE MULTIPLIERS - 3 TON (Continued)
Furnaces
KW
TM8E100C16MP11
0.96
TM8E100C20MP11
0.95
TM8E120C16MP11
0.96
TM8E120C20MP11
0.95
TM8V080C16MP12C
0.96
TM8V100C16MP12C
0.95
TM8V100C20MP12C
0.95
TM8V120C20MP12C
0.97
TM8X080C16MP11
0.93
TM8X100C16MP11
0.93
TM8X100C20MP11
TM8X120C20MP11
TM8Y080C16MP11
KW
TM8Y100C16MP11
0.97
TM8Y100C20MP11
0.95
TM8Y120C20MP11
0.95
TM9E080B12MP12
0.96
TM9E080C16MP11
0.95
TM9E080C16MP12
0.98
TM9E080C20MP12
0.97
5855837-CTG-A-0220
1500
80
80
80
80
75
67
72
57
62
62
38.0
40.2
36.3
37.4
36.9
26.1
19.8
36.3
35.0
29.1
2.02
2.04
2.12
2.13
2.13
37.4
39.9
35.5
36.2
35.8
26.2
19.9
35.5
35.6
28.9
2.22
2.23
2.33
2.33
2.33
36.4
39.3
34.5
34.9
34.6
26.1
19.8
34.5
34.9
28.5
2.46
2.46
2.56
2.56
2.56
35.2
38.2
33.4
33.5
33.1
25.8
19.5
33.4
33.5
28.1
2.72
2.72
2.83
2.82
2.82
33.7
36.9
32.1
32.0
31.5
25.3
19.1
32.1
32.0
27.4
3.02
3.02
3.12
3.12
3.12
31.9
35.1
30.6
30.4
29.7
24.6
18.5
30.6
30.4
26.6
3.34
3.35
3.45
3.45
3.44
29.8
32.9
28.9
28.7
27.6
23.6
17.6
28.9
28.7
25.6
3.70
3.71
3.81
3.81
3.80
27.4
30.4
27.0
27.0
25.4
22.3
16.6
27.0
27.0
24.4
4.10
4.11
4.21
4.21
4.19
Coil
T.C.
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
CF/CM/CU36C
1.01
CF/CM/CU36C
1.01
CF/CM/CU36C
1.02
CF/CM/CU36C
1.02
80
80
67
72
38.9
40.8
27.8
20.5
2.13
2.16
38.4
40.7
28.4
21.0
2.33
2.35
37.6
40.2
28.7
21.1
2.56
2.57
36.4
39.3
28.7
21.0
2.83
2.83
34.9
37.9
28.3
20.6
3.13
3.13
33.0
36.1
27.5
19.9
3.45
3.46
30.7
33.8
26.3
18.9
3.81
3.82
28.1
31.1
24.7
17.6
4.21
4.23
S.C.
KW
0.99
0.95
0.98
0.95
0.99
0.95
0.98
0.95
0.98
0.96
0.98
0.96
0.99
0.95
0.99
0.95
0.98
0.97
0.98
0.97
0.98
0.95
0.98
0.95
0.98
0.97
0.98
0.97
0.98
0.95
0.98
0.95
0.98
0.98
0.98
0.96
0.99
0.97
0.98
0.95
35