Specifications And Performance Claims - GE GXSHC40N Owner's Manual And Installation Instructions

Water softening system
Table of Contents

Advertisement

Available languages

Available languages

Specifications and Performance Claims

This model is efficiency rated. The efficiency rating is valid only at the minimum stated salt dose. The softener has
a demand initiated regeneration (D.I.R) feature that complies with specific performance specifications intended to
minimize the amount of regenerant brine and water used in its operation.
The softener has a rated salt efficiency of not less than 4,000 grains of total hardness exchange per pound of
salt (based on sodium chloride), and shall not deliver more salt than its listed rating or be operated at a sustained
maximum service flow rate greater than its listed rating. This softener has been proven to deliver soft water for at
least ten continuous minutes at the rated service flow rate. The rated salt efficiency is measured by laboratory test
described in NSF/ANSI Standard 44. These tests represent the maximum possible efficiency that the system can
achieve. Operational efficiency is the actual efficiency after the system has been installed. It is typically less than the
efficiency, due to individual application factors including water hardness, water usage, and other contaminants that
reduce the softener's capacity.
Model
Rated Capacity* (Grains@ Salt Dose)
Rated Efficiency** (Grains/Pound of Salt @ Minimum Salt Dose)
Water used during Regeneration (gallons/grains)
Total Water Used per Regeneration @ Maximum Salt Dose
Amount of High Capacity Ion Exchange Resin (lb/cu.ft.)
Resin Tank Nominal Size (in., dia. x height)
Service Flow Rate (gpm)
Pressure Drop at Rated Service Flow (psig)
Water Supply Maximum Hardness (gpg)
Water Supply Maximum Clear Water Iron (ppm)***
Water Pressure Limits (minimum-maximum psi)****
Water Temperature Limits (minimum-max. °F)
Maximum Flow Rate to Drain (gpm)
These systems conform to NSF/ANSI 44 for the
specific capacity claims as verified and substantiated
by test data.
*
Testing was performed using pellet grade
sodium chloride as the regenerant salt.
**
Efficiency rating is valid only at the lowest stated
salt dosage. These softeners were efficiency
rated according to NSF/ANSI 44.
*** Extent of iron removal may vary with conditions.
The capacity to reduce clear water iron is
substantiated by WQA test data. State of
Wisconsin requires additional treatment if water supply contains greater than 5 ppm clear water iron. Refer to
Cleaning Iron Out of the Water Softening System section.
**** Canada working pressure limits: 1.4–7.0 kg/cm
Specifications
Contaminant
Radium 226/228
Test parameters include: pH = 7.5±0.5, flow rate = 7.5 gpm
.
2
3
GXSHC40N
11,700 @ 2.3 lbs
31,500 @ 8.7 lbs.
40,000 @ 15.1 lbs.
5,090 @ 2.3 lbs.
2.7 /1000
37.0 gallons
57.56/1.11
9 x 40
9.5
12.7
110
8
20-125
40-120
2.3
Performance Claims
Influent
Challenge
Level
Barium
10 ±10% mg/L
25 pCi/L
and dynamic pressure = 35±5 psig
Maximum
Allowable Product
Water Level
2.0 mg/L
5pCi/L

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents