Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Keithley Manuals
Multimeter
172A
Instruction manual
Keithley 172A Instruction Manual page 54
Hide thumbs
1
2
3
Table Of Contents
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
page
of
139
Go
/
139
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
THEORY
OF OPERATION
SWI-CH
V
A
n
2 WI RE/4 WI RE"*
2
WIRE/4
WIRE""
INSTRUCTION
MANUAL
DigitsI Mullimet*r
Modela
172A. 173A
TABLE 5-l.
(CONIT)
Summary of
Pushbutton
Switching
STYLE
"Interlock
*Interlock
Push-Push
Push-Push
Push-Push
Push-Push
Push-Push
Push-Push
SETTING
In
In
In
In
out
In
Out
In
Out
REMARKS
DMM is
set
to
V mode.
Overriaes
A and R
functions
due
to
interlocked
pushbuttons.
DMM~is set
to A mode.
Overrides
V and 5
functions
due to
interlocked
pushbuttons.
DMM is
set
to n mode.
Overrides
V and A
functions
due
to
interlocked
pushbuttons,
also
overrides
DC/AC switch.
:':NOTE
If
V, A, and R pushbuttons
are
OUT simultan-
eously,
no function
will
be selected,
the
input
terminals
will
be open-circuited,
and
the
DMM will
display
V.
The displayed
read-
ing
is meaningless.
DMM is
set
to measure
AC (either
V or A).
Not
functional
when
set
to R.
DMM ib set
to measure
DC (either
V or A).
DMM is
set
to
low ohms function.
DMM is
set
to high
ohms function.
DMM is
set
for
4-WIRE
ohms measurements.
Upper
pair
of
terminals
are
used
for
Volt-
age sensing.
Lower
pair
of
terminals
are
used
for
ohms source.
Lower
pair
of
terminals
are
useable
only
in 4-WIRE
3 mode
and are
open
circuited
for
all
other
conditions.
DMil is
set
for
conventional
2-WIRE
ohms
measurements.
Upper
pair
of
terminals
must
be used.
Lower
pair
of
terminals
are
open-
circuited.
Only
functional
when
set
to R.
5-4
Table of
Contents
Previous
Page
Next
Page
1
...
51
52
53
54
55
56
57
58
Advertisement
Table of Contents
Related Manuals for Keithley 172A
Multimeter Keithley 171 Instruction Manual
Digital multimeter (91 pages)
Multimeter Keithley 177 Instruction Manual
Microvolt dmm and battey pack (54 pages)
Multimeter Keithley 179A Instruction Manual
Trms (33 pages)
Multimeter Keithley 175 Instruction Manual
(69 pages)
Multimeter Keithley 178 Instruction Manual
(3 pages)
Multimeter Keithley 1765 Service Manual
(60 pages)
Multimeter Keithley 150 A Instruction Manual
(24 pages)
Multimeter Keithley 165 Instruction Manual
Digital multimeter (60 pages)
Multimeter Keithley 195A Quick Reference Manual
(11 pages)
Multimeter Keithley 196 Instruction Manual
Dmm (160 pages)
Multimeter Keithley 135 Operator's Manual
(12 pages)
Multimeter Keithley 160B Instruction Manual
(76 pages)
Multimeter Keithley 191 Instruction Manual
(80 pages)
Multimeter Keithley 169 Instruction Manual
(52 pages)
Multimeter Keithley 169 Instruction Manual
(51 pages)
Multimeter Keithley AUTO-PROBE 167 Instruction Manual
(76 pages)
Related Products for Keithley 172A
Keithley 171
Keithley 177
Keithley 1788
Keithley 179A
Keithley 175
Keithley 1765
Keithley 176
Keithley 150 A
Keithley 150AR
Keithley 164
Keithley 164TT
Keithley 165
Keithley 197A
Keithley 197
Keithley AUTO-PROBE 167
Keithley 1792
This manual is also suitable for:
173a
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL