4.12 Power management
function
• Cooking zones are grouped according
to the location and number of the
phases in the hob. See the illustration.
• Each phase has a maximum
electricity loading of 3700 W.
• The function divides the power
between cooking zones connected to
the same phase.
• The function activates when the total
electricity loading of the cooking
zones connected to a single phase
exceeds 3700 W.
• The function decreases the power to
the other cooking zones connected to
the same phase.
• The heat setting display of the
reduced zones changes between two
levels.
Power management function with
Power limitation function
When you set the Power limitation
function to 4.5 kW or less, power of the
hob is divided between all cooking
zones.
When you set the Power limitation
function to more than 4.5 kW, power of
the hob is divided between two cooking
zones in a pair.
4.13 Hob²Hood
It is an advanced automatic function
which connects the hob to a special
hood. Both the hob and the hood have
an infra — red signal communicator.
Speed of the fan is defined automatically
on basis of mode setting and
temperature of the hottest cookware on
the hob. You can also operate the fan
from the hob manually.
For most of the hoods the
remote system is originally
deactivated. Activate it
before you use the function.
For more information refer to
hood user manual.
Operating the function automatically
To operate the function automatically set
the automatic mode to H1 – H6. The hob
is originally set to H5. The hood reacts
whenever you operate the hob. The hob
recognizes temperature of the cookware
automatically and adjusts the speed of
the fan.
Automatic modes
Auto‐
matic
light
Mode
Off
H0
Mode
On
H1
Mode
On
3)
H2
ENGLISH
11
Boil‐
2)
Frying
1)
ing
Off
Off
Off
Off
Fan
Fan
speed 1
speed 1

Advertisement

Table of Contents
loading

Table of Contents