Hepa Filter / Deodorizing Filter; Filter Replacement; Troubleshooting - Sharp KC-G51R Operation Manual

Hide thumbs Also See for KC-G51R:
Table of Contents

Advertisement

Available languages

Available languages

HEPA FILTER /
DEODORIZING FILTER
Remove the dust on the HEPA Filter and
Deodorizing Filter.
CAUTION
• Do not wash the filters. Do not expose to sunlight.
HEPA FILTER
Maintain only the tagged
Tag
surface. Do not clean up
the opposite surface. The
filter is fragile, so be careful
not to apply too much
pressure.
DEODORIZING FILTER
Both surfaces can be
maintained.
The filter may be broken
if being too much power
is applied on it, so please
handle it with care.
Some odors absorbed by the filters will break down over time,
causing additional odors. Depending on usage conditions, and
especially if the unit is used in environments significantly more
severe than a normal household, these odors may become
noticeable sooner than expected.
Replace the filter in those cases or if dust is unable to be
removed after maintenance.
How to install the Float and the Tray Panel
Tray Panel
KC-G61R
KC-G51R / KC-G41R
Float
1. Insert the float under
Tab
this tab.
Float
Cross-Section view
3. Insert the tab on the
other side of the float
2. Insert the tab of
into the hole.
the float into the hole.

FILTER REPLACEMENT

LIFE OF FILTERS
Filter life varies depending on the room environment,
usage conditions, and location of the unit.
Lifespan of HEPA filter and Deodorizing filter and
replacement suggestions are based on purifying
a room in which 5 cigarettes are smoked per day and
the unit's dust collection and deodorizing performance
has declined to half the level of a new filter.
We recommend replacing the filter more frequently if
the unit is used in conditions significantly more severe
than a normal household.
•HEPA Filter
About 10 years after opening
•Deodorizing Filter About 10 years after opening
•Humidifying Filter About 10 years after opening
Replacement Filter Model
Consult your dealer when purchasing a replacement
filter.
Replacement
KC-G61R
KC-G51R
KC-G41R
Filter
HEPA Filter
FZ-D60HFE
FZ-D40HFE
FZ-D40HFE
(1 unit)
Deodorizing
FZ-G60DFE
FZ-G40DFE
FZ-G40DFE
Filter(1 unit)
Humidifying
FZ-G60MFE
FZ-G60MFE
FZ-G60MFE
Filter(1 unit)
Shaft (white)*
Filter Frame (white)*
Humidifying Filter
Filter Frame (gray)*
Shaft (gray)*
*Do not dispose these parts.
Disposing of filters
Dispose of used filters according to local laws and
regulations.
HEPA Filter material:
• Filter: Polypropylene
• Frame: Polyethylene
Deodorizing Filter material:
• Filter: Paper
• Frame: ABS resin
Humidifying Filter material:
• Filter: Rayon, polyester
E-15

TROUBLESHOOTING

Before contact for service, review the troubleshooting chart below to make sure that the problem is not a unit malfunction.
SYMPTOM
REMEDY
Odor and smoke persists.
• Check the filters. If they appear to be extremely dirty, clean or replace them.
(Ref. E-15)
The Cleanliness Monitor is blue
• The air may have been dirty when the unit was plugged in. Unplug the unit, wait
even when the air is not clean.
one minute, and then plug the unit in again.
The Cleanliness Monitor light is
• Dirty or clogged dust(sensitive) sensor openings interfere with sensor operation.
red even when the air is clean.
Gently clean the sensor filter or the back panel. (Ref. E-13).
The unit makes a clicking or
• The unit may make clicking or ticking sounds when it is generating ions.
ticking sound.
Air discharged from the unit
• Check to see if the filters are extremely dirty.
has an odor.
• Clean or replace the filters. (Ref. E-13, E-14, E-15)
• Use only fresh tap water. Using other water sources risks the growth of mold,
fungi, or bacteria.
The unit does not operate when
• Make sure the unit is installed in a location in which the sensors can detect
cigarette smoke is in the air.
cigarette smoke.
• Check to see if the dust(sensitive) sensor openings are blocked or clogged. If
they are blocked or clogged, clean the sensor filter or the back panel.
(Ref. E-13)
The FILTER RESET Indicator
• Whenever after performing maintenance or replacing the filters, connect the
Light is on.
power cord to an outlet and then press the Filter Reset Button. (Ref. E-13)
The Front Display is turned off.
• When Light control is set to "Auto", the light automatically turns off when the
room is dark. Moreover, when Light control is set to "Turn off", the light is always
off. If you do not want the light to be off, set Light control to the "Darker" setting.
(Ref. E-11)
The Humidify Light on the
• The room has reached the appropriate level of humidity and has stopped
Front Display does not light up
humidifying.
when the tank is empty.
• Check the styrofoam float for impurities. Clean the Humidifying Tray. Make sure
that the unit is on a level surface. (Ref. E-14)
The water level in the tank does
• Check to see if the Humidifying Tray and Water Tank are correctly installed.
not decrease or decreases
Check the Humidifying Filter. (Ref. E-14)
slowly.
• If the filter is extremely dirty, clean or replace it. (Ref. E-15)
The Cleanliness Monitor
• The Cleanliness Monitor automatically changes color when the dust (sensitive)
changes color frequently.
sensor and odor sensor* detect impurities. If you are concerned about the
change, you can change sensor sensitivity.
(Ref. E-11,E-12) (*KC-G61R / KC-G51R)
There is a discrepancy between
• There is a difference in the humidity level within the same room.
the unit's Humidity Monitor
• The sensor have different measurement parameters.
and another hygrometer in the
• If the monitor indicates wattage or temperature, switch the display by pressing
room.
the DISPLAY SELECT button. (Ref. E-10)
The unit PM2.5 Light does not
• Outdoor and indoor as well as the home environment (the volume of traffic
match weather report or other
nearby, number of stories in home, etc.) may cause a reading different than
local PM2.5 data.
local PM2.5 data.
o
"
C" Light flashing
• The room is suitable for viruses to survive due to low room temperature. We
recommend you adjust the temperature using heating appliances. (Ref. E-9)
• The room temperature and humidity is high. We recommend that you drink
some water or lower the room temperature. (Ref. E-10)
ERROR DISPLAY
If error occurs repeatedly, contact the Sharp Service Center.
DIGITAL INDICATION
Make sure that the Humidifying Filter and Humidifying Tray are
properly installed, and then turn the power to ON again.
Unplug the unit, wait one minute, and then plug the unit in again.