ON TIMER

Select the length of time you want. The unit automatically
starts once the selected time is passes.
(with the unit OFF)
2hour
4hour
6hour
8hour
CANCELLATION
14hour
12hour
10hour

PATROLLING FUNCTION

The sensor detects a state requiring attention to room temperature and humidity during operation and tells it with
Patrolling Light. Both "Dry and Low temperature patrolling" and "High temperature and High humidity patrolling"
work. (This function informs a room condition. The unit cannot adjust temperature or lower humidity)
DRY AND LOW TEMPERATURE PATROLLING
It tells that the room is dry or the room temperature is low.
When Patrolling Light turns to red, the unit operates with airflow a little stronger during Intelligent mode (Auto mode).
If the beeping sound is set to "ON". (Ref. E-12)
Patrolling
Light
Humidity / Temperature
(for 30 seconds)
Monitor
"%" Light turns on
Red
C" Light flashing
o
"
Green
(Normal)
When the room is dry and the room temperature is low, viruses survive more easily. We recommend
that you increase humidity with humidification setting and temperature using heating appliances
according to your room environment.
Material source: Dr. Makoto Shoji, Director of Shoji internal medicine and pediatrics clinic
in Sendai City, Miyagi Prefecture, Japan
Right figure Absolute humidity
*1
Virus environment
(1)
Environment which is less suitable for
Over 11 g
viruses to survive
(2)
11 g or less
Environment where viruses can survive
Environment which is suitable for
(3)
7 g or less
viruses to survive
*1 The absolute humidity is the total mass of water vapor present in 1 m
temperature and is expressed in g. While humidity generally used for a weather forecast is called
relative humidity, which is the ratio of the partial pressure of water vapor to the equilibrium vapor
pressure of water at a given temperature and is expressed in %. Therefore, the absolute humidity is
approximately 8 g at 15
C and 18 g at 30
C even at the same relative humidity of 60 %.
o
o
*2 Survival rate of viruses emitted in air after 6 hours under each environment.
NOTE
• It does not notify of the existence of viruses themselves.
• Patrolling Light's illuminating "Green" does not assure
prevention of infection. Use it as a reference to make an
environment to prevent infection during typical daily life.

OFF TIMER

Select the length of time you want. The unit automatically
stops once the selected time is reached.
(with the unit ON)
1hour
2hour
4hour
8hour
Temperature
and humidity
Indoor environment
area (Figure
Beeping sound
Dry
Beep (once)
Beep (once)
Low temperature
Not dry or low
None
temperature
Survival rate
*2
0 % to small percent
5 %
20 %
3
of air regardless of
Relative humidity (%)
• While adjusting humidity to approximately 55 % to 65 %
during operation in Intelligent mode (Auto mode), the
unit controls humidification, but does not make changes
according to the virus' environment.
E-9

SELECTING DISPLAY

CANCELLATION
Humidity
The beeping sound of Patrolling Function is set to "Off" at the default. You can change it to "On" or "Cancel
Patrolling Function". (Ref. E-11, E-12)
HIGH TEMPERATURE AND HIGH HUMIDITY PATROLLING
It tells high temperature and high humidity. When Patrolling Light turns to orange or red, the unit stops humidification
automatically. (However, it is in MAX/MED/LOW mode, it does not stop humidification)
Patrolling
Light
Humidity / Temperature
below)
Monitor
Red(Flashing)
(3)
Red
(1)·(2)
Orange
Green
We recommend that you drink some water or lower the room temperature.
Guideline for preventing heatstroke in daily life <Source: website of Japanese Society of Biometeorology>
Overview of life
Temperature
activities to be noted
standard
D Danger
(
C)
o
Risks that could occur
in all life activities
C Heavy alert
Risks that could occur
B Alert
in middle level or higher
life activities
Risks that could occur
A Caution
in hard life activities
NOTE
This is not a function to prevent heatstroke. Please use this function as an assistance.

PLASMACLUSTER ION ON/OFF

When the Plasmacluster function is ON, the Plasmacluster
Ion light on the Front Display is on. (Ref.E-6)
(with the unit ON)
ON
Temperature
Wattage
If the beeping sound is set to "ON". (Ref. E-12)
Beeping sound
(for 30 seconds)
C" Light flashing
o
Beep・・・(for 30 seconds)
"
Beep・・・(for 30 seconds)
o
"
C" Light turns on
o
"
C" Light turns on
None
(Normal)
None
Precautions
Elderly people are highly likely to suffer from
heartstroke even in a resting state. Avoid going out
and move to a cooler room.
Avoid blazing sun when going out and pay attention
to an increase of room temperature when staying in
a room.
Rest regularly when doing exercise or intense work.
Generally the risk is low, but people may suffer
when doing hard exercise or hard work.
E-10
OFF
more
more
3 sec.
3 sec.
Temperature
and humidity
Indoor environment
area (Figure
below)
D
High temperature
and high humidity
C
Relatively high
temperature and high
B
humidity
Not high temperature
A
nor high humidity
(