Download Print this page

Emerson fisher 6365 Series Installation Manual

Advertisement

Quick Links

Installation Guide
D102692X014
English – April 2016
Introduction
This installation guide provides instructions for
installation, startup and adjustment. To receive a copy
of the instruction manual, contact your local Sales
Office or view a copy at www.fisher.com. For further
information refer to: Type 6365 and 6358 Series
Instruction Manual, D102692X012.
PED Categories
This product may be used as a safety accessory with
pressure equipment in the following Pressure Equipment
Directive categories. It may also be used outside of the
Pressure Equipment Directive using sound engineering
practice (SEP) per table below. For information on the
current PED revision see Bulletin: D103053X012.
PRODUCT SIZE
CATEGORIES
Type 6365, DN 6 / 1/4 in.
Type 6358, 1/4 NPT
Specifications
Pilot Descriptions
Type 6365: Set pressure range from 35 mbar to
0.14 bar / 14 in. w.c. to 2 psig. This pilot has a high
gain restriction standard.
Type 6358: Set pressure range from 0.21 to 8.6 bar /
3 to 125 psig. This pilot has a restriction plug.
Type 6358B: Set pressure range from 0.14 to
8.6 bar / 2 to 125 psig. This pilot is available with a
high, medium or low gain restriction.
Type 6358EB: Set pressure range of 5.2 to
24.1 bar / 75 to 350 psig. This pilot is available
with a high or low gain restriction.
Type 6358EBH: Set pressure range of 17.2 to
41.4 bar / 250 to 600 psig. This pilot is available
with a high or low gain restriction.
Maximum Relief (Inlet) Pressure (Including Buildup)
Depends upon maximum inlet pressure for
complete relief valve as specified in appropriate
main valve bulletin.
Pilot Set Pressure Ranges
See Table 1
Proof Test Pressure
All Pressure Retaining Components have been
proof tested per Directive
Temperature Capability
-29 to 66°C / -20 to 150°F
1. The pressure/temperature limits in this installation guide or any applicable standard limitation should not be exceeded.
2. Set pressure is defined as the pressure at which the pilot starts to discharge.
FLUID TYPE
SEP
1
(1)(2)
(1)
Type 6365 and 6358 Series
Pressure Connection
1/4 NPT (internal)
Installation
Only qualified personnel should install
or service a regulator. Regulators
should be installed, operated and
maintained in accordance with
international and applicable codes
and regulations and Emerson Process
Management Regulator Technologies,
Inc. instructions.
If the regulator vents fluid or a leak
develops in the system, it indicates that
service is required. Failure to take the
regulator out of service immediately may
create a hazardous condition.
Personal injury, equipment damage or
leakage due to escaping fluid or bursting
of pressure-containing parts may result
if this regulator is overpressured or
is installed where service conditions
could exceed the limits given in the
Specifications section, or where
conditions exceed any ratings of the
adjacent piping or piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to prevent
service conditions from exceeding limits.
Additionally, physical damage to the
regulator could result in personal injury
and property damage due to escaping
(1)
fluid. To avoid such injury and damage,
install the regulator in a safe location.
Clean out all pipelines before installation of the
regulator and check to be sure the regulator has not
been damaged or has collected foreign material during
shipping. For NPT bodies, apply pipe compound to the
external pipe threads. For flanged bodies, use suitable
line gaskets and approved piping and bolting practices.
Install the regulator in any position desired, unless
otherwise specified, but be sure flow through the body
is in the direction indicated by the arrow on the body.
WARnInG
!

Advertisement

loading

Summary of Contents for Emerson fisher 6365 Series

  • Page 1 This product may be used as a safety accessory with international and applicable codes pressure equipment in the following Pressure Equipment and regulations and Emerson Process Directive categories. It may also be used outside of the Management Regulator Technologies, Pressure Equipment Directive using sound engineering Inc.
  • Page 2 Type 6365 and 6358 Series Table 1. Pilot Set Pressure Ranges and Control Spring Information SPRInG RAnGE WIRE DIAMETER FREE LEnGTH PILOT TYPE SPRInG COLOR psig 6365 35 mbar to 0.14 bar 14 in. w.c. to 2 psig Yellow 1.78 0.070 54.1 2.13...
  • Page 3 Type 6365 and 6358 Series A6920 B2619-2 TYPE 6358 PILOT InTERIOR vIEW TYPE 6358B PILOT InTERIOR vIEW Figure 1. Type 6358 and 6358B Pilots Type 6365 Pilot Description Body Assembly Spring Case Body Plug Plug/Stem Assembly Diaphragm Assembly Connector Cap Control Spring Spring Seat Plug/Stem Guide...
  • Page 4 Technologies, Inc. All rights reserved. 09/18. McKinney, Texas 75070 USA Singapore 128461, Singapore The Emerson logo is a trademark and service mark of Emerson T +1 800 558 5853 T +65 6777 8211 Electric Co. All other marks are the property of their prospective owners.

This manual is also suitable for:

Fisher 6358 series6358b6358eb6358ebh