WARNINGS AND SAFETY INSTRUCTIONS GENERAL WARNING This instruction contain general caution information for use in Pool and SPA pump installation application. Specified Pump model function should be refer to particular manual. Components such as the filtration system, pumps and heater must be positioned so as to prevent their being used as means of access to the pool by young children.
SUCTION ENTRAPMENT HAZARD This pump produces high levels of suction and creates a strong vacuum at the main drain at the bottom of your pool and spa. This suction is so strong that it can trap adults or children under water if they come in close proximity to a pool or spa drain or a loose or broken drain cover or grate.
1. APS SERIES PLASTIC PUMP OVERVIEW 1. Hydrau-Power APS series pump delivery Emaux latest technology in pump design. 2. It is constructed in reinforced plastic pump body in lightweight and corrosion-resistant that suitable for marine applications.
1450RPM 50Hz U.S.g.p.m 1200 H(ft) H(m) 55 60 65 70 75 80 85 85 Q(m³/h) Q(LPM) 1500 2250 3000 3750 4500 3. IMPORTANT SAFETY INSTRUCTIONS The user guide you are holding includes essential information on the safety measures to be implemented for installation and start-up.
5. INSTALLATION 5. 1 LOCATION The pump should be located nearby as close as possible the pool or spa to reduce friction loss and improve efficiency. It is recommended at least 1.5 meter from pool water and 3 meters according to Canadian code. 1.
6. ELECTRICAL WIRING-3 PHASE This power pump demand licensed or certified electrician or qualified pool installer to ensure there is adequate protection between the pump motor and mains power supply according to individual countries safety code. The pump has power cord with plug attached on the plug, plug it to a power socket with circuit breaker to isolate the motor from the mains power for over load protection.
6. 1 DIRECT ON LINE Direct On Line (DOL) starting is the simplest, cheapest and most common starting method. It actually gives the lowest temperature rise within the motor during startup of all the starting methods. But the drawback is starting current can be 3-8 time of full load current.
The factory connection is a Dealta conneciton 3 phase power 4 wires power line connection Green& yellow Groudn wire location Terminal Box Motor Roation Arrow 1. Every power lines have to be protected by circuit breaker for over load to isolated the motor from the mains power and provide protection to motor.
Contactor Protection Relay with Motor Circuit timer Breaker The contact plate on the six terminals has to be removed. 6. 3 VARIABLE FREQUENCY DRIVE(VFD) The pump is possible to drive by variable frequency driver for better starting and energy saving purpose. The connection is simple, it is just connect the 3 phase output of the variable frequency drive to the pump in Delta or Star configuration according to the motor plate on the motor.
Besides current and power rating of the VFD is the key parameter to drive the motor, the EMC filter between VFD and motor is the most critical device to prevent the motor bearing, shaft and insulation system from being damage by VFD inverter high frequency bearing current noise.
7. START UP 1. Verify the pump shaft turn freely. 2. Check the mains voltage, current and frequency are accordingly to the name plate. 3. Never run pump dry! Running pump dry may cause damage to the mechanical seal causing leakage and flooding.
The pump mechanical seal requires no lubrication and service. To avoid drops in pressure and pre-filter Basket damage. The pre-filter basket of the pump should be visually inspected at least once a week. Remove the clear lid and the basket and clean debris from basket. Inspect the lid O-ring;...
10. TROUBLE SHOOTING Problem Corrective Action 1. No water in Pre-filter Lid is not tight Damaged lid O-Ring 2. Water level below Skimmer 3. Pre-filter or Skimmer Basket clogged Closed Valve in Piping System Pump Will Not Prime 4. Air leak in Suction Line 5.
Page 17
Descriptions Diameter of inlet and outlet of the pump Diameter of the Pipe Air-bleed hole should be installed at the highest point Holding the pipes with racks so as to prevent too much load on the branch of the pump, and the racks should be coated with corrosion resisting material.
It is not transferable to anyone who subsequently purchases the product from you. It excludes all expendable parts. During the warranty period, Emaux authorized reseller will repair or replace defective parts with new parts or, at the option of Emaux, serviceable used parts that are equivalent or superior to new parts in performance.
Page 20
EMAUX WATER TECHNOLOGY CO., LTD YOUR PREMIER SUPPLIER www.emauxgroup.com...
Need help?
Do you have a question about the APS Series and is the answer not in the manual?