The battery is not installed
Incorrect battery installation
No display on the display
The battery is low
The display cable is not plugged properly
The color of the filter cartridge
The timing module is damaged
lifetime icon does not change
Filter cartridge is blocked
Flow rate is reduced
Filter cartridge service life comes to end
The water inlet pressure is too low
Carbon leakage and filter
Excessive water inlet pressure
bottle break
There is no gasket or raw material belt at
Water supply T-valve leakage
water supply T-valve
The water pressure fluctuates greatly and the
ultrafiltration membrane breaks
Filter water is turbid
Leakage of O-ring on
Wrong connection of inlet and outlet pipes
No filter water
Filter cartridage is blocked

Troubleshooting Instructions

If the water purifier demonstrates abnormal behavior,
please follow the troubleshooting methods below. If it
remains unsolved, please contact the purchasing store
or the nearest special maintenance department of our
company for help (available around the country), you
can also call Moen national after-sales service hotline
for help.
Possible Reasons
O
Filter Cartridage Level 3
16
Solutions
Install battery
Re-install the battery
Replace battery
Replug the display cable
Contact the After Sales staff
Replace filter cartridage
Replace filter cartridage
Install booster pump
Install the pressure reducing valve and
replace the filter catridge
Check and re-install water supply T-valve
Add pressure reducing valve and replace the
Flter Catridge Level 3
O
Replace O-ring
Ensure the water purifier inlet is connected with
water supply T-valve, and the outlet is connected
with the water purifying tap.
Replace filter cartridage