that Exhaust Gas Temperature is not available on channels 2, 3, 4, and 5). You may also
disable the channel by programming the "Disabled" value into this field.

2.5.3 Channel #0 - #5 Instance

Each temperature measurement with a given source must have a unique instance number
associated with it. This enables monitoring software and displays to distinguish different
temperature measurements from one another. For example, if a channel is programmed to
transmit a source type of Exhaust Gas Temperature and the instance for that channel is set to
a value of 0, then no other Exhaust Gas Temperature measurement on the network may use
an instance number of 0.

2.5.4 Channel #0 - #5 Label

Each channel that can be monitored by the TMP100 may be programmed with a text label that
will be displayed in monitoring software and displays that recognize device labels, such as the
Maretron N2KView Vessel Monitoring System and the Maretron DSM250 display. The label
will let you assign an easy-to-remember text label (example: "Forward Bilge Pump") to make it
easy for you to identify the device as you are configuring the monitoring software or display, as
well as when alerts are generated.

2.5.5 Device Label

This entry allows you to assign a text label to the device. This label is visible in Maretron
analysis and display products and allows you to easily identify the particular device.

2.5.6 Advanced Configuration...

Certain parameters do not normally need to be set in order for normal operation, but are
included in an advanced configuration section for use in special situations.
®
2.5.6.1 NMEA 2000
PGN Enable/Disable
®
The TMP100 is capable of transmitting NMEA 2000
messages (or PGNs) associated with
monitored switch circuits. You may individually enable or disable each of these messages. You
may also change the rate of transmission of each of these messages if desired.

2.5.6.2 Restore Factory Defaults

Selecting this configuration option causes all stored parameters in the TMP100 to be reset to
the values they contained when the unit was manufactured.

2.5.6.3 Installation Description...

The TMP100, along with all other Level A certified NMEA 2000 devices, has two user-
programmable installation description fields. You may program these fields with information
specific to the device, such as date installed, the initials/name of the installer, the physical
location of the device, etc. This configuration option will allow you to program the values of
these fields.