Technical Support - Maretron TMP100 User Manual

Temperature module
Hide thumbs Also See for TMP100:
Table of Contents

Advertisement

Electrical
Parameter
Operating Voltage
Power Consumption
Load Equivalence Number (LEN)
Reverse Battery Protection
Load Dump Protection
Mechanical
Parameter
Size
Weight
Environmental
Parameter
IEC 60945 Classification
Degree of Protection
Operating Temperature
Storage Temperature
Relative Humidity
Vibration
Solar Radiation
Corrosion (Salt Mist)
Electromagnetic Emission
Electromagnetic Immunity
Safety Precautions

6 Technical Support

If you require technical support for Maretron products, you can reach us in any of the following
ways:
Revision 1.2
9 to 32 Volts
Value
3.50" x 4.20" x 2.03"
(88.9mm x 106.7mm x 51.6mm)
13 oz. (368.5 g)
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
4 times 7 days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Conducted and Radiated Emission per IEC 60945-9
Conducted, Radiated, Supply, and ESD per IEC 60945-10
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Telephone:
Fax:
E-mail:
World Wide Web:
Mail:
Value
DC Voltage
50 mA
NMEA 2000
1
NMEA 2000
Yes
Indefinitely
Yes
Energy Rated per SAE J1113
Including Flanges for Mounting
Value
Exposed
IP64
-25°C to 55°C
-40°C to 70°C
93%RH @40°C per IEC60945-8.2
1-866-550-9100
1-602-861-1777
support@maretron.com
http://www.maretron.com
Maretron, LLP
Attn: Technical Support
rd
9014 N. 23
Ave Suite 10
Phoenix, AZ 85021 USA
Comment
®
Interface
®
Spec. (1LEN = 50 mA)
Comment
2
per IEC 60945-8.7
Page 11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tmp100-01

Table of Contents