N2KView (with the optional Alerts module), a DSM150 display, or a DSM250 display can instruct the SMS100 to connect to the mobile network and transmit a user-selected alert message to user-programmed telephone numbers, alerting you quickly to conditions onboard your vessel that require attention anywhere you have cellular network coverage.
1.5.1 SIM Card In order to use the SMS100, you must install a SIM card with an active SMS plan that is capable of connecting to a mobile network in the area in which you are using the SMS100.
Please check Maretron’s website for the latest information. 2.3.2 Installing the SIM Card In order to use the SMS100, the SIM card must be installed into the SMS100. To install the SIM card, please perform the following steps: 1) Remove the four screws from the bottom of the SMS100 enclosure.
(or an NMEA 2000 compatible cable) by connecting the female end of the cable to the SMS100 (note the key on the male connector and keyway on the female connector). Be sure the cable is connected securely and that the collar on the cable connector is tightened firmly. Connect the other end of the cable ®...
Connector Face Views 2.5.2 Cellular Antenna Connection The SMS100 has one external SMA cellular antenna connector. This connector is intended for use only with the included TG.10.0113 cellular antenna. Screw the antenna onto the SMA connector and tighten until snug. Rotate the antenna so that it is a vertical orientation for best signal reception.
Manual, DSM150 User’s Manual, or DSM250 User’s Manual, as appropriate, for details. 4.2 Receiving Messages You may send a message to the SMS100 in order to receive a predefined message showing the current status of various parameters on the vessel.
• Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove paint or markings or may corrode the SMS100 enclosure or seals. Do not use any cleaners containing acetone, as they will deteriorate the plastic enclosure.
Page 12
060160 ISO Transport Protocol, Data Transfer 060928 ISO Address Claim 065240 ISO Address Command 126208 NMEA Request/Command/Acknowledge Periodic PGNs 130834 SMS Status (Maretron Proprietary) 10 seconds 130835 SMS Text Message (Maretron Proprietary) On Receipt Electrical Parameter Value Comment Operating Voltage...
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CONTAINS FCC ID: XPYLISAU200 9 Technical Support If you require technical support for Maretron products, you can reach us in any of the following ways: Telephone: 1-866-550-9100...
SMS100 User's Manual 10 Installation Template Please check the dimensions before using the following diagram as a template for drilling the mounting holes because the printing process may have distorted the dimensions. 3.9” (99.1mm) 6.0” (152.4mm) 6.225” (158.1mm) Figure 4 – Mounting Template Page 10 Revision 1.0...
11 Maretron (2 Year) Limited Warranty Maretron warrants the SMS100 to be free from defects in materials and workmanship for two (2) years from the date of original purchase. If within the applicable period any such products shall be proved to Maretron’s satisfaction to fail to meet the above limited warranty, such products shall be repaired or replaced at Maretron’s...