Cellular Antenna Connection; Configuring The Sms100; Advanced Configuration; Device Instance - Maretron SMS100 User Manual

Sms (text) module
Table of Contents

Advertisement

® ®
®
Figure 2 – NMEA 2000
Connector Face Views

2.5.2 Cellular Antenna Connection

The SMS100 has one external SMA cellular antenna connector. This connector is intended for
use only with the included TG.10.0113 cellular antenna. Screw the antenna onto the SMA
connector and tighten until snug. Rotate the antenna so that it is a vertical orientation for best
signal reception.

3 Configuring the SMS100

The SMS100 has several configurable parameters, which are shown below including the
default values. If you are not using the default values, then you will need to refer to the
corresponding section for configuring the SMS100 appropriately. You may configure the
®
SMS100 using a Maretron DSM150 or DSM250 display or Maretron N2KAnalyzer
software.

3.1 Advanced Configuration

3.1.1 Device Instance

Program this parameter to the desired instance number for this device. You can program this
parameter to any value between 0 and 252. The default device instance is 0

3.1.2 Installation Description

®
This entry allows you to modify the NMEA 2000
installation description text strings. You can
enter any information you like here, such as the date the unit was installed, or the location in
®
which it was installed, for later reference. Tools such as Maretron N2KAnalyzer
allow you to
view these values later. The default installation description is blank text.

3.1.3 Restore Factory Defaults

This option restores all settings on the SMS100 device to their factory default states.
Revision 1.0