Congratulations on your purchase of the Maretron Temperature Module. Maretron has designed and built your TMP100 to the highest standards for years of dependable and accurate service. Maretron's TMP100 measures the temperature for up to 6 temperature probes and reports the ®...
Please consider the following when choosing a mounting location. 1. The TMP100 is waterproof, so it can be mounted in a damp or dry location. 2. The orientation is not important, so the TMP100 can be mounted on a horizontal deck, vertical bulkhead, or upside down if desired.
® ® The NMEA 2000 connector can be found on the side of the enclosure. The NMEA 2000 connector is a round five pin male connector (see Figure 2). You connect the TMP100 to an ® ® NMEA 2000 network using a Maretron NMEA 2000...
Temperature Probe 5 (positive terminal) Temperature Probe 5 (negative terminal) Before attempting to connect the TMP100 to the temperature probes, determine the type of system you will be monitoring. The TMP100 supports the connection and monitoring of two different system types; 1) Exhaust Gas Temperature probes (Section 2.4.2.1), or 2) thermistor type probes (ring/under bolt probes, immersion probes, and ambient air probes;...
T0+/T0- (pins 1 and 2) or T1+/T1- (pins 3 and 4). Please refer to Figure 3 for connecting the TMP100 to a TP-EGT-1 exhaust gas temperature probe. Please be sure to connect the red wire from the EGT probe to the negative “-” terminal, and the yellow wire from the EGT probe to the positive “+”...
(pins 7 and 8), T4+/T4- (pins 9 and 10), or T5+/T5- (pins 11 and 12). Please refer to Figure 4 for connecting the TMP100 to a TR3K ring/under bolt thermistor temperature probe, TP-AAP-1 ambient air temperature probe, or TP-IP-1 immersion temperature probe.
0. 2.5.4 Channel #0 - #5 Label Each channel that can be monitored by the TMP100 may be programmed with a text label that will be displayed in monitoring software and displays that recognize device labels, such as the Maretron N2KView Vessel Monitoring System and the Maretron DSM250 display.
Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove paint or markings or may corrode the TMP100 enclosure or seals. Do not use any cleaners containing acetone, as they will deteriorate the plastic enclosure.
TMP100 User's Manual 5 Technical Specifications As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretron products are designed to be accurate and reliable; however, they should be used only as aids to navigation and not as a replacement for traditional navigation aids and techniques.
Conducted, Radiated, Supply, and ESD per IEC 60945-10 Safety Precautions Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12 6 Technical Support If you require technical support for Maretron products, you can reach us in any of the following ways: Telephone: 1-866-550-9100...
TMP100 User's Manual 7 Installation Template Please check the dimensions before using the following diagram as a template for drilling the mounting holes because the printing process may have distorted the dimensions. Figure 5 – Mounting Surface Template Page 12...
8 Maretron (2 Year) Limited Warranty Maretron warrants the TMP100 to be free from defects in materials and workmanship for two (2) years from the date of original purchase. If within the applicable period any such products shall be proved to Maretron’s satisfaction to fail to meet the above limited warranty, such products shall be repaired or replaced at Maretron’s...
Page 18
TMP100 User's Manual This page intentionally left blank Page 14 Revision 1.2...
Page 19
4: Atmospheric Pressure – This field is filled by the TMP100 with a value indicating “data not available”. 5: Reserved bits – The TMP100 sets all bits in this field to a value of “1”. PGN 130311 – Environmental Parameters (not recommended for new designs; included...
Page 20
5: Set Temperature – The TMP100 sets this field to a value indicating “data not available”. 6: Reserved bits – The TMP100 sets all bits in this field to a value of “1”. PGN 130316 –Temperature, Extended Range The TMP100 uses this PGN to provide a regular transmission of various temperatures. The factory default for periodic transmission rate is once every two seconds.
Page 21
Field 1: Manufacturer Code – This field contains Maretron’s NMEA 2000® manufacturer code, which is 137. 2: Reserved – The TMP100 sets all bits in this field to a value of “1”. 3: Industry Group – This field contains the Marine industry group code, which is 4.