201110 - 9200W ELECTRIC START GENERATOR
Problem
Engine is running but no AC output.
Engine hunts or falters.
Repeated circuit breaker tripping.
For other issues and technical support:
Technical Support Team
Toll Free 1-877-338-0999
support@championpowerequipment.com
Cause
Poor cord connection.
Circuit breaker is open.
Faulty brush assembly.
Loose wiring.
GFCI tripped.
Other.
Engine governor defective.
Dirty fuel valve.
Carburetor is dirty and running lean.
Choke lever in wrong position.
Overload.
Faulty power cords or device.
Circuit breaker still too hot.
32
TROUbLESHOOTING
Solution
Check all connections.
Reset circuit breaker. Check all circuit breakers.
Replace brush assembly (Service Center).
Inspect and tighten wiring connections.
Reset GFCI receptacle breakers by first pushing
the TEST button then the RESET button until
green LED illuminates. Contact the help line.
Contact the help line.
Contact the help line.
Clean the fuel valve.
Contact the help line.
Move choke lever until it stops under "RUN"
position or push in completely.
Review load and adjust. See "Connecting
Electrical Loads."
Check for damaged, bare or frayed wires. Replace
defective device.
Let unit sit for 5 mins.