resideo Braukmann DirectConnect AMX300 Installation Instructions Manual

resideo Braukmann DirectConnect AMX300 Installation Instructions Manual

Mixing valve kits

Advertisement

Quick Links

Braukmann
AMX300 DirectConnect™
Mixing Valve Kits
Included in this box (see Fig. 1)
1.
AMX300 thermostatic mixing valve ("A")
2.
Cold water tee ("B")
3.
Flexible metal connector ("C")
4.
Thermostrip ("D")
5.
AMX300 Mixing Valve Installation Instructions
(literature # 62-3112)
6.
AMX300 Mixing Valve Kit Installation Instructions
(literature # 62-3113)
CONNECTOR
THREADS
CONNECTOR NUTS
Fig. 1. Mixing valve kit contents.
M38278
PIPE
ºF ºc
THREADS
140
60
138
58
136
57
134
56
132
55
130
54
128
53
126
52
124
51
122
50
120
49
118
48
116
47
CORRUGATED
114
46
112
44
110
43
SMOOTH
M29694B

Tools needed (not supplied)

1.
Wrench
2.
Pliers

Safety Definitions

These safety terms identify information you must read.
CAUTION
Indicates a hazardous situation which, if not avoided,
could cause bodily injury or property damage.
WARNING
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
GETTING STARTED
CAUTION
For the homeowner's comfort, safety and
convenience, it is recommended this mixing valve kit
be installed and serviced by a plumbing professional.
These instructions provide detailed instructions for
Installation and maintenance of the mixing valve kit.
You must read these instructions carefully and
completely to ensure proper installation.

Safety Precautions

WARNING
Water inside the water heater is very hot and presents
a scalding hazard.
Water temperatures in excess of 120 ºF (49 ºC) can
cause severe burns. Explain this to homeowner and
emphasize the risks associated with adjusting the
mixing valve settings.
U P
C
®
C
®
INSTALLATION INSTRUCTIONS
62-3113-05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Braukmann DirectConnect AMX300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for resideo Braukmann DirectConnect AMX300

  • Page 1 Braukmann AMX300 DirectConnect™ Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) Wrench Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates a hazardous situation which, if not avoided, could cause bodily injury or property damage. WARNING M38278 Indicates a hazardous situation which, if not avoided,...
  • Page 2 AMX300 DIRECTCONNECT™ MIXING VALVE KITS 3. This mixing valve kit MUST NOT be subjected to heat WARNING during installation as this may damage the internal components. Water inside the water heater is very hot and presents a scalding hazard. If the AMX300 mixing valve kit is being installed on a CAUTION water heater that is already operational, be careful when draining the hot water supply lines in...
  • Page 3 AMX300 DIRECTCONNECT™ MIXING VALVE KITS WATER CONNECTIONS 3/4 IN. NPT COLD WATER INLET The AMX300 mixing valve has an integral 1/2-in. FNPT Alternate Hot Water outlet port (marked with an embossed “AH” on the body of the valve) that draws unmixed, very hot COLD WATER water from the tank.
  • Page 4 AMX300 DIRECTCONNECT™ MIXING VALVE KITS 3. If compliance to ASSE 1017 code is required, install a INSTALLATION field supplied check valve in the cold water supply. In this case an expansion tank is required prevent exces- 1. Plastic thread protectors are installed in both ends of sive pressure in the system.
  • Page 5 AMX300 DIRECTCONNECT™ MIXING VALVE KITS TEMPERATURE ADJUSTMENT WARNING Increasing water temperature increases the risk of Prior to adjusting the hand wheel setting on the mixing valve, scald injury. Scalding may occur within 5 seconds at a the water heater must be operational and deliver hot water setting of 140°F (60°C).
  • Page 6 AMX300 DIRECTCONNECT™ MIXING VALVE KITS MAINTENANCE Resideo recommends that the AMX300 mixing valve kit be 3. Follow directions in the MAINTENANCE section of checked annually to ensure proper operation. In areas with “AMX300 Series DirectConnect™ Mixing Valve Installa- adverse water conditions, such as extremely hard water, tion Instructions”, Resideo literature # 62-3112 (sup-...
  • Page 7 AMX300 DIRECTCONNECT™ MIXING VALVE KITS 62-3113—05...
  • Page 8 Resideo Technologies, Inc. 1985 Douglas Drive North, Golden Valley, MN 55422 1-800-468-1502 www.resideo.com 62-3113—05 M.S. Rev. 03-20 | Printed in United States © 2020 Resideo Technologies, Inc. All rights reserved. This product is manufactured by Resideo Technologies, Inc. and its affiliates.

Table of Contents