Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
See models on page 2.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures or services performed by an unqualified person.
TECHNICAL MANU
TECHNICAL MANU
TECHNICAL MANU AL
TECHNICAL MANU
TECHNICAL MANU
DSX 16 SEER
Condensing Units
Copyright © 2009 Goodman Manufacturing Company, L.P.
AL
AL
AL
AL
RT6114006r3
September 2009

Advertisement

loading

Summary of Contents for Goodman DSX16

  • Page 1 • See models on page 2. RT6114006r3 This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does September 2009 not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person.
  • Page 2: Product Identification

    Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible Installation and repair of this unit WARNING WARNING...
  • Page 3 WARNING that is not design certified by damage, personal injury, or death, Goodman for use with this unit. do not store combustible materials or use gasoline or Serious property damage, personal injury, reduced unit other flammable liquids or vapors in the vicinity of this performance and/or hazardous conditions may result appliance.
  • Page 4: Product Design

    PRODUCT DESIGN DSX16 models are available in 2, 3 4 and 5 ton sizes and This unit is for outdoor installation only. Refer to minimum use R-410A refrigerant. They are designed for 208/230 volt figure for clearances from the sides of the unit to full walls and other objects.
  • Page 5: Condensing Unit Specifications

    CONDENSING UNIT SPECIFICATIONS DSX160241A* - DSX160601A* DSX160241A* DSX160361A* DSX160481A* DSX160601A* Cooling Capacity, BTUH 24,000 36,000 48,000 60,000 Compressor R.L. Amps 10.3 16.7 21.2 25.6 L.R. Amps 52.0 82.0 96.0 118.0 Low Pressure Switch Open 22 PSIG 22 PSIG 22 PSIG 22 PSIG Close 50 PSIG...
  • Page 6 CONDENSING UNIT SPECIFICATIONS DSX160241B* - DSX160361B* DSX160361B* DSX160241B* Cooling Capacity, BTUH 24,000 36,000 Compressor R.L. Amps 10.3 16.7 L.R. Amps 52.0 82.0 Low Pressure Switch Open 22 PSIG 22 PSIG Close 50 PSIG 50 PSIG High Pressure Switch Open 610 PSIG 610 PSIG Close 420 PSIG...
  • Page 7 DSX160241A*-LOW STAGE PERFORMANCE DATA...
  • Page 8 PERFORMANCE DATA DSX160241A*-LOW STAGE...
  • Page 9 PERFORMANCE DATA DSX160241B*-LOW STAGE...
  • Page 10 PERFORMANCE DATA DSX160241B*-LOW STAGE...
  • Page 11 DSX160361A*-LOW STAGE PERFORMANCE DATA...
  • Page 12 PERFORMANCE DATA DSX160361A*-LOW STAGE...
  • Page 13 PERFORMANCE DATA DSX160361B*-LOW STAGE...
  • Page 14 PERFORMANCE DATA DSX160361B*-LOW STAGE...
  • Page 15 DSX160481A*-LOW STAGE PERFORMANCE DATA...
  • Page 16 PERFORMANCE DATA DSX160481A*-LOW STAGE...
  • Page 17 DSX160601A*-LOW STAGE PERFORMANCE DATA...
  • Page 18 PERFORMANCE DATA DSX160601A*-LOW STAGE...
  • Page 19 DSX160241A*-HIGH STAGE COOLING PERFORMANCE DATA...
  • Page 20 COOLING PERFORMANCE DATA DSX160241A*-HIGH STAGE...
  • Page 21 COOLING PERFORMANCE DATA DSX160241B*-HIGH STAGE...
  • Page 22 COOLING PERFORMANCE DATA DSX160241B*-HIGH STAGE...
  • Page 23 COOLING PERFORMANCE DATA DSX160361A*-HIGH STAGE...
  • Page 24 COOLING PERFORMANCE DATA DSX160361A*-HIGH STAGE...
  • Page 25 COOLING PERFORMANCE DATA DSX160361B*-HIGH STAGE...
  • Page 26 COOLING PERFORMANCE DATA DSX160361B*-HIGH STAGE...
  • Page 27 COOLING PERFORMANCE DATA DSX160481A*-HIGH STAGE...
  • Page 28 COOLING PERFORMANCE DATA DSX160481A*-HIGH STAGE...
  • Page 29 COOLING PERFORMANCE DATA DSX160601A*-HIGH STAGE...
  • Page 30 COOLING PERFORMANCE DATA DSX160601A*-HIGH STAGE...
  • Page 31 PERFORMANCE DATA LOW STAGE - A DSX160241A* / CA*F3636C6**+TXV / MBE1200**-1B* DSX160361A* / CA*F3743*6A*+TXV / MBE1600**-1B* Conditions: 80°F IDB, 67°F IWB @ 600 CFM, LOW STAGE Conditions: 80°F IDB, 67°F IWB @ 800 CFM, LOW STAGE Outdoor Total Sensible Latent Total Outdoor Total...
  • Page 32 PERFORMANCE DATA HIGH STAGE - A DSX160361A* / CA*F3743*6A*+TXV / MBE1600**-1B* DSX160241A* / CA*F3636C6**+TXV / MBE1200**-1B* Conditions: 80°F IDB, 67°F IWB @ 1200 CFM, High Stage Conditions: 80°F IDB, 67°F IWB @ 800 CFM, High Stage Outdoor Total Sensible Latent Total Outdoor Total...
  • Page 33 PERFORMANCE DATA LOW STAGE - B DSX160361B* / CA*F3743*6**+TXV + MBE1600**-1B* DSX160241B* / CA*F3636*6**+TXV+MBE1200**-1* Conditions: 80°F IDB, 67°F IWB @ 800 CFM, LOW STAGE Conditions: 80°F IDB, 67°F IWB @ 540 CFM, LOW STAGE Outdoor Total Sensible Latent Total Outdoor Total Sensible Latent...
  • Page 34: Wiring Diagrams

    WIRING DIAGRAMS DSX160[24-60]1** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.