Velp Scientifica ECO8 Operation Manual

Velp Scientifica ECO8 Operation Manual

Thermoreactor with safety cover and prefixed temperatures and times
Hide thumbs Also See for ECO8:

Advertisement

Quick Links

Thermoreactor ECO8
with safety cover
and prefixed temperatures
and times
Operation Manual
IMPORTANT:
READ THE INFORMATION CONTAINED IN THE OPERATION MANUAL BEFORE USING THE
UNIT. THE MANUFACTURER DOES NOT ACCEPT RESPONSIBILITY FOR THE IMPROPER
USE OF THE EQUIPMENT OR FOR FAILURE TO FOLLOW INSTRUCTIONS.
The labels applied to the unit warn of the dangers to which the user may be exposed during use or
maintenance of the unitthermoreactor. The labels must be left on the unit and replaced if they are
no longer readable.
Danger Warning:
To prevent accidents associated with the use of this instrument
Start of Operations:
Read instructions for use and maintenance before using this instrument
SAFETY RULES
1) The heating plate if programmed, may reach a temperature of 150°C, this happens during the
heating phase but also during the cooling phase.
2) The containers and the products used during the work must be compatible with the temperature
set on the unit.
3) The instrument is equipped by a voltage changer accessibile on the rear panel which allows the
connection to electric nets with 230 V or 115 V.
Before connecting the instrument to electric supply verify that the voltage changer is on the position
corresponding to the supplied voltage.
CLEANING
Always unplug the unit before cleaning. The heating plate must be cool.
Use a damp cloth and not flammable, not aggressive detergents.
PERSONAL PROTECTION EQUIPMENT
The equipment used for personal protection must be compatible with the possible dangers deriving
from the working materials and from the glass vessels.
MAINTENANCE
According to the law on products guarantee our instrument must be repaired at our factory, save
different agreements with our agents. For more information see the "Maintenance" Chapter in this
manual.
GUARANTEE
Starts from the date of delivery note and is referred to the number of register of the single unit.
The manufacturer, engaged in a continuous improvement of his products reserves the right to
modify any of their characteristics without notice.
10001328/A1
1
Rev. 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECO8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Velp Scientifica ECO8

  • Page 1 Thermoreactor ECO8 with safety cover and prefixed temperatures and times Operation Manual IMPORTANT: READ THE INFORMATION CONTAINED IN THE OPERATION MANUAL BEFORE USING THE UNIT. THE MANUFACTURER DOES NOT ACCEPT RESPONSIBILITY FOR THE IMPROPER USE OF THE EQUIPMENT OR FOR FAILURE TO FOLLOW INSTRUCTIONS.
  • Page 2: Table Of Contents

    Velp Scientifica – ECO8 Manual CONTENTS 1. Introduction 2. Instrument description 3. Instrument accessories 4. Assembly and installation 5. Operation 5.1 Description of controls 5.2 Power interruptions 5.3 Safety features 6. Start of a cycle 7. Maintenance 7.1 Replacing fuses 8.
  • Page 3: Introduction

    All this allows a very good precision and reproducibility. The ECO8 thermoreactor is equipped by a voltage changer, accessibile on the rear of the instrument, allowing a connection to electric nets 230 V or 115 V.
  • Page 4: Assembly And Installation

    Velp Scientifica – ECO8 Manual 4. Assembly and installation The instrument is equipped by a voltage changer accessibile on the rear panel which allows the connection to electric nets with 230 V or 115 V. ATTENTION ! Before connecting the instrument to electric supply verify that the voltage changer is on the position corresponding to the supplied voltage.
  • Page 5: Power Interruptions

    Velp Scientifica – ECO8 Manual Temperature When the instrument is turned on, the four temperature LED’s LED’s will not be lit. This signals that a work cycle is not in progress. When a preset temperature is selected the corresponding LED will light. All of the LED’s will blink when the selected temperature is higher than the block temperature.
  • Page 6: Start Of A Cycle

    Velp Scientifica – ECO8 Manual Start of a cycle A work cycle is started by pressing the Start/Temp. button. The default option is set at 150°C and 120 minutes as shown by the corresponding LED’s. It is possible to select other temperatures and times by pressing the corresponding buttons.
  • Page 7: Disposal

    If a control is required it is possible to measure the temperature of the heating block using an original Velp Scientifica thermometer in the hole located in the upper part of the block.
  • Page 8: Technical Features

    Velp Scientifica – ECO8 Manual 11. Technical features Description: code F101A0127 220-240/50-60 Power supply V/Hz 110-120/50-60 Power Weight Dimensions (WxHxD) 135x95x230 150 – 120 – 100 – 70 Selectable temperatures °C 1’ 30 – 60 – 120 and Selectable times infinite ...
  • Page 9: Electric Scheme

    Velp Scientifica – ECO8 Manual 12. Electric scheme 1) 5x20mm retarded fuse 3.15A 2) General lighted switch 3) Voltage changer electronic card 4) Safety thermostat 5) Electric resistance 6) Electronic card 7) Pt100 probe 10001328/A1...
  • Page 10: Suggestions

    Velp Scientifica – ECO8 Manual 13. Suggestions Any suggests and advice would be greatly appreciated to enable us to constantly improve this instruction manual. e-mail: service@velp.it 10001328/A1...
  • Page 11 Velp Scientifica – ECO8 Manual Declaration of compliance manufacturer VELP SCIENTIFICA s.r.l. address Via Stazione, 16 USMATE (MI) Italy Under our responsability declare that the product is in according with the following standards: EN 61010-1/2001 EN 61326-1/2000 And satisfies the essential requirements of directives:...
  • Page 12 Velp Scientifica – ECO8 Manual Thanks for choosing a VELP’s product ! Since 1983 Velp offers to the professional in the field a range of sophisticated and reliable equipment which make available high levels of know-how and operative capacity at competitive price.

Table of Contents