Heat pump Water Heater Operation and Installation Manual ELECTRICITE Model HP80M8-9 HP110M8-9 HP150M8-9 Please read this manual carefully prior to your use of this water heater. The appearance of the water heater given in this manual is for reference only.
9.Faults and protection ......................38 10.Product Fiche ........................39 Dear users of Haier, Thank you for choosing Haier products. Please read this manual carefully and follow the operation and safety instruction to ensure best installation and utilization of the product.
Page 3
4. This product must be installed outdoors 5. This product cannot be discarded or scrapped at will. If necessary, please contact Haier's after-sales team to obtain the correct disposal method. When the product is disposed of, the refrigerant in the system needs to be recovered.
Page 4
Safety instructions (to be followed at any time) Interpretation of marks and symbols Failure to respect these instructions may lead to serious malfunctions of the device and to risks for the user Instructions with this warning mark shall be strictly followed during operation. They relate to product and body safety of users.
Page 5
Safety instructions (to be followed at any time) The outlet water temperature Means for disconnection from of a water heater is typically the main supply having a higher than the temperature contact separation in all poles indicated on the display. Hot that provide full...
Page 6
Safety instructions (to be followed at any time) Rotate the safety valve handle Water heaters shall once a month. The valve equipped with a dedicated works well if there is water power line residual flowing out, otherwise check current circuit breakers. The for blocking and replace the action current...
Page 7
Safety instructions (to be followed at any time) 1.Ask your dealer or qualified personnel to carry out installation work.Do not attempt to install the product yourself. Improper Installation may result in water leakage, electric shocks, fire or explosion. 2.Keep this manual where the user can easily nd it. 3.Install the product in accordance with the instructions in this installa- tion manual.
Page 8
Safety instructions (to be followed at any time) 1.Do not install the appliance at any place where there is danger of flammable gas leakage.In the event of a gas leakage, build-up of gas near the appliance may cause a fire to break out. 2.Take adequate steps to prevent the outdoor unit being used as a shelter by small animals.Small animals making contact with electrical parts can cause malfunctions, smoke or fire.
Safety instructions (to be followed at any time) Installation Instructions Electrical Safety Requirements 1. The surrounding conditions (ambient temperature, direct sunlight and rainwater) shall be noticed during electrical wiring, with effective protective measures being taken. 2. Copper wire cable in line with local standards shall be used as the power line and connector wire.
Page 10
Safety instructions (to be followed at any time) Maintenance Site Requirements 1. The maintenance site shall be provided with favorable ventilation and must be flat. Arrangement of the maintenance site inside the basement is not allowed. 2. Welding zone and non-welding zone shall be divided at the maintenance site, and shall be clearly marked.
Page 11
Safety instructions (to be followed at any time) 4. In case leakage is suspected, the open fire at the site shall be evacuated or be put out. 5. In case welding is required at the leakage position, all the refrigerants shall be recov- ered, or be isolated at a position far from the leak point with a stop valve.
Instructions on transportation and storage 1. During transportation or storage, the heat pump water heater shall be packed in the undamaged package to avoid damage to appearance and performance of the product; 2. During transportation or storage, the heat pump water heater shall be in the upright position;...
51/58kg 54/62kg 64/83kg The COP and noise level data was tested in Haier lab. The COP values obtained with external air temperature of 7°C and 14°C, inlet water temperature of 10°C and set temperature of 55°C (according to EN 16147).
Description of parts and components Heat pump structure Condensate outlet Inlet for cold Hot water water/drain outlet outlet Air outlet Air inlet Accessories Part Heat pump Instruction Safety Drainage pipe for Support plate name water heater manual condensate water valve 1(HP80M8-9) Quantity 1(HP110M8-9) 2(HP150M8-9)
Page 15
Description of parts and components Exploded view Description Electric cover Electric heater Display panel Cover for display Capacitor for compressor Controller panel Compressor Four-way valve Electronic expansion valve Evaporator Top cover Air grille Air channel - front Motor Air channel - back Support plate Power cord 19 Pipe for water outlet...
Installation introduction Installation precaution - Do not install the water heater in the position where exposed to gas, vapours or dust. - Install the appliance on a flat, solid surface.The surface can support the machine weight and the condensate water can be drained freely. - Noise due to operating and air flow do not bother neighbors.
Page 18
Installation introduction Installation dimensions Unit:mm Model 1694 HP150M8-9...
Page 19
Installation introduction Installation dimensions Note: These two expansion bolts can support 200kg weight at least . Please use the expansion bolts adapted to your wall material. Note: Please dismantle the elbows before removing the top cover. Installation angle refer to the following After the installation is completed, it is necessary diagrams:...
Page 20
Installation introduction Installation dimensions Note: These two expansion bolts can support 250kg weight at least . Please use the expansion bolts adapted to your wall material. Note: Please dismantle the elbows before removing the top cover. Installation angle refer to the following After the installation is completed, it is necessary diagrams:...
Page 21
Installation introduction Air connection - Remove air grille first. click y Meter-long x Meter-long φ160mm φ160mm φ160mm Available pressure 30 Pa Drop Equivalent Pressure 1m-long (Pa) Smooth 0.6 /1 meter tube Bellows 1 /1 meter Installation suggestions: x + y < 36 m (Smooth tube) x + y <...
Page 22
Installation introduction Advised positions Garage or laundry room (without ducts): -Unheated room. -Enables recovery of the free energy released by your vehicle’s engine when switched off after use or by household appliances in operation. Laundry room (with one duct): -Unheated room. -Enables recovery of the free energy released by your vehicle’s engine when switched off...
Page 23
Installation introduction Installation caution When making the connections, you should respect the standards and local directives. - Before making the connection, rinse the water inlet pipes, in order not to introduce metal or other particles into the tank. - Select copper pipes for pipeline connection. - The inlet water pressure is between 0.1~0.5MPa.
Page 24
Installation introduction Pipeline installation diagram Installation A Thermostatic valve Check valve 230V 50Hz Hot water outlet Outlet of condensate water Pressure Stop Check valve valve relief valve safety valve Drain valve Water outlet of Cold water inlet safety valve Water outlet Installation B(for France only) Connected to water inlet of the water tank...
Page 25
Installation introduction Electrical connections precautions WARNING - Only qualified professionals may carry out electrical connections, always with the power off. - The earthing shall comply with local standards. - Water heaters shall be equipped with a dedicated power line and residual current circuit breakers.
Page 26
Installation introduction Off-peak power signal wire connection 123kwh Auto Off-peak power signal wire (2*0.75mm ,Black wire) Power cable (3*1.5mm...
Page 27
Installation introduction Wiring diagram Compressor CN11 CN12 Capacitor Four-way Discharge temperature valve CN13 sensor MAIN BOARD CN10 Defrost temperature White sensor ︳ Ambient temperature Brown sensor White Suction temperature sensor ︳ Black Water tank temperature sensor ( upper) Compressor ︳ CN7/8 CN24 Water tank temperature...
Operation and functions Display Menu button Rotary knob Return button Functions & Protections Electrical leakage protection The control system of this machine features an electricity leakage protection function. 3-minutes protection When starting the machine after electricity input, the system will start after approximately 3 minutes ,which is considered to be normal.
Page 29
Description of the icons Symbol Description Current date display 11/18/2022 11:30 Current time display PV/SG/HC signal display Sterilization function display Mute function display WIFI function display Heat pump heating indication Electric auxiliary heating indication Indication of hot water availability Lock function display -Optimised management of the heat pump and backup element for guaranteed comfort ;...
Page 30
Function Introduction power on 1. When powered on for the first time, all icons will light up for 3 seconds, and the buzzer will beep once to enter the power on state. Enter the initialization settings and select the confirmation language (Chinese/English/French/Italian/German/Spanish/Portuguese/Polish) 、...
Page 31
Function Introduction Boost function After selecting Boost, press the Rotary knob to confirm and make an ON/OFF selection. After the selection is completed, if the setting is successful, the prompt will indicate successful setting, otherwise the prompt will indicate failed setting.BOOST mode has the highest priority and can be started in any mode.Only valid once.
Page 32
Function Introduction Mode selection ECO mode After selecting ECO by rotating the button, enter the selection interface, where you can select the ECO time period, such as Same every day - Different every day. ELEC mode After selecting ELEC, press Rotate knob to confirm, and then prompt whether the setting is successful or not.
Page 33
Function Introduction Mode selection VAC mode After selecting VAC, press the Rotary knob to confirm and enter the start and end time period setting. After the time setting is completed, select the OK button to automatically return to the menu interface. The main interface displays VAC mode. In this mode, the system activates the water tank protection function (anti freezing, etc.) and prepares hot water in advance based on the vacation return date entered by the user.
Page 34
Function Introduction Accumulated quantity display function After selecting information, press Rotary knob to confirm. After entering the selection interface, there are four types of information that can be queried: Energy Accumulation - Energy consumption - Operation information - Message reset, all selected by rotating the Rotary knob.
Page 35
Function Introduction Settings After selecting Settings, press the Rotary knob to confirm and enter the selection interface. There are 6 options to choose from, including date, connection, language, temperature, HP, and volume, all of which are selected by rotating the button. Time settings After selecting DATE by rotating the button, the color of the year deepens.
Page 36
Function Introduction Language settings After selecting LANGUAGE, enter the language selection for a total of 8 languages. After confirmation, it will automatically return to the menu. Target Temperature&Unit Settings After selecting TEMP, you can set the temperature unit and temperature target value. After confirming the selection, return to the main interface.
Checking and maintenance Top Cover Removal Remove the screw in the left with a screwdriver; Rotate the top cover counterclockwise until you can take it off. Checking of the main control board Use a screwdriver to remove the screw. Controller panel Display panel Cleaning of the fan - Check the cleanliness of the fan one time per year.
Faults and protection Digital Release Fault type Action indication Communication failure between Wi-Fi Communication fault module and control board Operating temperature protection Air exhaust temperature protection Compressor protection After fault is solved, Evaporation high temperature switch on power protection supply for release Compressor over-current Over-current protection protection...