Download Print this page

Jenn-Air JED8230 Installation Manual page 2

Electric convertible cooktop
Hide thumbs Also See for JED8230:

Advertisement

Available languages

Available languages

Installing Cabinetry Over Your Jenn-Air Grill
A* = 30² (76.2 cm) minimum clearance between the top of
the cooking platform and the bottom of an unprotected
wood or metal cabinet.
A* = 24² (60.96 cm) minimum clearance when bottom of
wood or metal cabinet is protected by not less than
1/4² (0.635 cm) FLAME RETARDANT millboard
covered with no less than no. 28 MSG sheet steel,
0.015² (0.038 cm) stainless steel, 0.024² (0.061 cm)
aluminum or copper.
Dotted lines
indicate
range hood
construction
*
To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet
storage is to be provided, the risk can be reduced by
installing a range hood that projects horizontally a
minimum of 5 inches beyond the bottom of the cabinets.
Installer Installation Suggestions
1. Chamfer all exposed edges of decorative laminate to
prevent damage from chipping.
2. Radius corners of cutout and file to insure smooth
edges and prevent corner cracking. Recommend
1/4² ² ² ² or 3/8² ² ² ² diameter drill in each corner.
3. Rough edges, inside corners which have not been
rounded and forced fits can contribute to cracking of the
counter top laminate.
4. Countertop must be supported within 3² of cutout.
CAUTION
Warranty is void on JENN-AIR equipment installed
other than as recommended by manufacturer.
Recommended wall caps and transitions must be
utilized for proper operation and installation.
SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE
Electrical Wiring Information
The neutral of this unit is grounded to the frame through the
green grounding wire. If local conditions do not permit
grounding of theneutral, untwist or disconnect the green
wire and connect the green wire to ground in accordance
with local codes. Connect the white neutral to the service
neutral.
Proper Electric Supply
You must provide an adequate electrical supply system as
required for your cooktop. All wire connections must be in
accordance with local codes and properly insulated. Check
with local utility for governing electrical codes and
ordinances. In the absence of local electrical codes, the
National Electrical Code, NFPA No. 70, governing electric
range installations must be followed. A copy of the National
Electrical Code, NFPA No. 70, can be obtained by writing to:
NATIONAL FIRE PROTECTION ASSOC.
Batterymarch Park
Quincy, Massachusetts 02269
A three-wire, single phase, A.C. 120/240 volt 60 cycle
electrical system (properly circuit protected to meet Local
Codes of NFPA No. 70) must be provided. Unit must be
properly grounded in accordance with local wiring code. The
chart below recommends the minimum circuit protector and
wire size if the appliance is the only unit on the circuit. If
smaller sizes of wire are used, the unit efficiency will be
reduced and a fire hazard may be created. It is advisable
that the electrical wiring and hookup be accomplished by a
competent electrician.
RECOMMENDED MINIMUM
CIRCUIT PROTECTION
K.W. RATING
IN AMPERES
ON SERIAL PLATE
0 -
4.9
5.0 -
6.9
7.0 -
9.9
10.0 - 11.9
12.0 - 14.9
2
WIRE SIZE,
REMOVE
AWG
KNOCKOUT
20
12
30
10
40
8
50
8
60
6
NO
NO
NO
**YES