MOUNTING REC ALPHA PURE SERIES PANELS WITH CONTINOUS RAILS PARALLEL TO LONG SIDE OF THE PANEL

A continous rail (or other support structure) spans the complete underside of the panel.

Fig. 4: Clamping of REC Alpha Pure Series panels with rails parallel to long side of the panel

0
Legend
Clamping zone
Rail position
Rail position
Once a module is secured in each of the 4 zones (fig. 2), additional clamps, i.e., ≥5, may be freely located on panel frame without
affecting the warranty. Loads marked with a
REC's internal testing process.
CAUTION
The center point of each clamp and the minimum grip length must be fully located in the same clamping zones to be rated to that load (fig. 4).
If the panel is secured in zones with different load values, it is rated to the lowest load value only.
10
REC Installation Manual - REC Alpha Panels - IEC 61215 /61730
Rev 13 - 11.22
700 mm [27.5 in]
20-40 mm
Clearance Gap
Test Load
(Design Load)
+1200 Pa / -1200 Pa *
0 - 700 mm
(+800 Pa / -800 Pa)
0 - 200 mm
200 - 300 mm
Ref: PM-IM-23
700 mm [27.5 in]
40-60 mm
Test Load
(Design Load)
+3000 Pa / -2400 Pa
(+2000 Pa / -1600 Pa)
+1200 Pa / -1200 Pa *
X
(+800 Pa / -800 Pa)
+800 Pa / -800 Pa *
X
(+533 Pa / -533 Pa)
*
were not certified as part of IEC 61215/61730 testing; these have been evaluated by
0
>60 mm
<20 mm
Test Load
Test Load
(Design Load)
(Design Load)
+5400 Pa / -2400 Pa
(+3600 Pa / -1600 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
X
X
X