This does not apply to damages due to a panel fault, in cases of loss of life, bodily injury or damage to health or in the event of a grossly negligent breach of obligations on the part of REC SOLaR PTE. LTD. and/or in the event of an intentional or grossly negligent breach of obligations by a legal representative or vicarious agent.
PaNEl HaNdliNg In order to avoid damage to the solar cells and other components, all REC solar panels should be handled with care and protected from damage at all times. all warnings and instructions on the packaging should be observed. Follow these guidelines when unpacking, transporting, carrying, installing or storing panels: •...
The solar panels must not be exposed to artificially concentrated light. ENviroNMENtal faCtors REC solar panels are designed to provide decades of durable and stable output in installations up to 2000 m above sea level. ambient operating temperatures must be between -40° and +85°C.
PaNEL INSTaLLaTION REC solar panels are designed for capturing solar radiation and are not suitable for use as overhead or vertical glazing. The IP rating of the junction box provides a level of protection that allows panels to be mounted in any orientation (see product technical specifications for exact rating).
MouNtiNg MEtHods: ClaMPiNg WitH rails ParallEl to tHE sHort sidE REC N-Peak solar panels secured by clamping to mounting rails has been found to comply with IEC 61215 & IEC 61730 requirements for downward pressure,e.g., snow, of up to 7000 Pa (4666 Pa design load*) and upward pressure,e.g., wind, of up to 2400 Pa (1600 Pa design load*) according to the instructions below (*design loads apply a safety factor of 1.5 to the stated test load, e.g., test load 7000 Pa / 1.5 = 4666 Pa design load).
MouNtiNg MEtHods: ClaMPiNg WitH rails ParallEl to tHE loNg sidE REC N-Peak solar panels secured by clamping to mounting rails has been found to comply with IEC 61215 & IEC 61730 requirements for downward pressure,e.g., snow, of up to 5400 Pa (3600 Pa design load*) and upward pressure,e.g., wind, of up to 2400 Pa (1600 Pa design load*) according to the instructions below (*design loads apply a safety factor of 1.5 to the stated test load, e.g., test load 5400 Pa / 1.5 = 3600 Pa design load).
MouNtiNg MEtHods: MouNtiNg HolEs REC N-Peak panels can be mounted utilizing the four elongated holes (11 x 6.6 mm) on the underside of the panel at a distance of 382.5 mm from the corner (fig. 6) in conjunction with a device, e.g., screws, lockbolts or structural blind fasteners, with specifications suitable for the installation (fig. 7).
HolEs Each corner of the REC panel frame has small drainage holes spaced 55 mm from the corner of the panel frame that allow water caused by rain, condensation, snow melt, cleaning or any other process to exit the frame easily and minimize damage caused by freezing and thawing (fig. 9). These holes must not be used for mounting the panel, and they must not be covered by any part of the mounting structure.
CONNECTIONS aND CONNECTORS The connector type(s) used on REC solar panels are indicated in the product specifications at the rear of this manual. The connector IP rating is only valid when they are correctly connected. all connectors and cables must be secure and tight as well as electrically and mechanically sound.
The majority of the panel components can be recycled. For installations in the European Union, REC solar panels are subject to WEEE regulations. The symbol in fig. 12 as found on the label on the rear of the panel indicates that this product shall not be treated as household waste and must be disposed of at an appropriate collection point for the recycling of electrical and electronic equipment.
ENviroNMENt installation site • REC solar panels may only be installed on closed bodies of fresh water where water salinity does not exceed 25 mS/cm at 25°C (15 PSU). This specifically excludes mounting on sea and ocean applications. •...
Series; indicates type/name can include any of the suffixes: ECO, BLK, BLK2, Black, XV, Mono (M in product code), e.g., RECxxxTP2SM 72 XV; REC TwinPeak 2S Mono 72 XV. The object of the declaration described above is in conformity with the relevant Union harmonisation legislation: 2014/35/EU "Directive of the European Parliament and of the Council on the harmonisation of the laws of the Member States relating...
DOCUMENT HISTORY date revision reason 07.2018 First release 01.2019 Update to warranty conditions, addition of REC N-Peak Black Series 08.2019 Updated Datasheets REC Installation Manual - N-Peak - IEC 61215 /61730 Rev C - 07.19 Ref: NE-06-22...
Page 19
‘retro-fit’ system made by third-party manufacturers. MLPE devices may be used on REC solar panels where desirable or mandatory (note that the certification testing of solar panels does not include testing with MLPE devices). When installing an MLPE device on an REC solar panel, follow the instructions provided by the device manufacturer and the instructions specific for REC solar panels given below.