This does not apply to damages due to a panel fault, in cases of loss of life, bodily injury or damage to health or in the event of a grossly negligent breach of obligations on the part of REC SOLAR PTE. LTD. and/or in the event of an intentional or grossly negligent breach of obligations by a legal representative or vicarious agent.
PANEL HANDLING In order to avoid damage to the solar cells and other components, all REC solar panels should be handled with care and protected from damage at all times. All warnings and instructions on the packaging should be observed. Follow these guidelines when unpacking, transporting, installing or storing panels: •...
Application Class REC solar panels are rated for use in electrical Application Class A, Protection Safety Class II; at hazardous levels of voltage (>35V), current(>8A) and power (>240W) where general contact access is anticipated (panels qualified for safety through IEC 61730-1 and -2).
The solar panels must not be exposed to artificially concentrated light. ENVIRONMENTAL FACTORS REC solar panels are designed to provide decades of durable and stable output in installations up to 2000 m above sea level. Ambient operating temperatures must be between -40° and +85°C.
CLAMP SPECIFICATIONS REC modules must be secured with a torque between 12 - 25 Nm. Clamp installation must be carried out according to the manufacturer’ s instructions, including specific hardware and torque requirements. Ensure the clamps used are suitable for the planned installation and expected system design loads.
Page 8
Mounting using clamps The above named REC 72-cell product families can be secured with continous rails using clamps where both clamps and rails are located within the constraints shown in fig. 6. Mounting with continous rails utilizing clamps has been found to be in compliance with IEC 61215 & IEC 61730 requirements for test loads of up to 5400 Pa (design load of 3600 Pa*) downward force and 2400 Pa (design load of 1600 Pa) upward force according to the clamping position (*stated design loads (DL) apply a safety factor of 1.5 to the test load, e.g., 5400 Pa / 1.5 = 3600 Pa).
Page 9
Mounting using clamps The above named REC 72-cell product families can be secured with short rails using clamps where both clamps and rails are located within the constraints shown in fig. 7. Mounting with short rails utilizing clamps has been found to be in compliance with IEC 61215 & IEC 61730 requirements for test loads of up to 1400 Pa (design load of 933 Pa*) downward and upward force according to the clamping position (*stated design loads (DL) apply a safety factor of 1.5 to the test load, e.g., 5400 Pa / 1.5 = 3600 Pa).
Mounting holes All REC 72-cell panels have been certified for installation using the four elongated holes (11 x 6.6 mm) on the underside of the panel frame at a distance of 460 mm from the short side edge (fig. 8), utilizing rails and bolts matching the specifications in fig. 9. Installation of REC 72-cell panels using mounting holes has been found to be in compliance with IEC 61215 &...
CONNECTIONS AND CONNECTORS The connectors used on REC solar panels are specified in the product specifications at the rear of this manual. The given IP rating is only valid when the connectors are correctly mated. All connectors and cables must be checked to ensure they are secure and tight, as well as electrically and mechanically sound.
The majority of the panel components can be recycled. For installations in the European Union, REC solar panels are subject to WEEE regulations. The symbol in fig. 14 as found on the label on the rear of the panel indicates that this product shall not be treated as household waste and must be disposed of at an appropriate collection point for the recycling of electrical and electronic equipment.
INSTALLATION ENVIRONMENT Installation site • REC solar panels may only be installed on closed bodies of fresh water where water salinity does not exceed 25 mS/cm at 25°C (15 PSU). This specifically excludes mounting on sea and ocean applications. •...
‘retro-fit’ system made by third-party manufacturers. MLPE devices may be used on REC solar panels where desirable or mandatory (note that the certification testing of solar panels does not include testing with MLPE devices). When installing an MLPE device on an REC solar panel, follow the instructions provided by the device manufacturer and the instructions specific for REC solar panels given below.
Series; indicates type/name can include any of the suffixes: BLK, BLK2, Black, XV, Mono (M in product code), e.g., RECxxxTP2SM 72 XV; REC TwinPeak 2S Mono 72 XV. The object of the declaration described above is in conformity with the relevant Union harmonisation legislation: 2014/35/EU "Directive of the European Parliament and of the Council on the harmonisation of the laws of the Member States relating...