Commissioning
1.
Plug the power cord into the socket on the back of the station.
2. Plug the power cord into an earthed wall outlet. The station is protected against electrostatic
discharge and must be earthed for full performance.
3. Make sure that the power switch is off before plugging or unplugging the soldering iron cord.
Otherwise, the circuit board may be damaged.
4. Assemble the soldering iron stand as shown.
5. Connect the soldering iron to the 8-pin output on the bottom right of the station.
6. Place the soldering iron on the soldering iron stand as shown.
7. Dampen the sponge with water, squeezing out excess water beforehand. Tips can be damaged
if used with a dry sponge.
8. The device is now ready for operation.
Setting the temperature
1.
Switch the device on.
2. A number between 200 and 480 is shown on the display, indicating the set temperature.
3. The display panel then toggles and displays the actual temperature.
4. Set the desired target temperature by pressing the Up/Down buttons.
5. While the target temperature is being adjusted, the display shows the currently set target tem-
perature. After a few seconds, the display panel will switch to the actual temperature.
6. The temperature control range is from 200 ℃ to 480 ℃.
Setting the digital offset
The device is equipped with a digital offset function for tip adjustment. To set the tip temperature:
1.
Set the desired working temperature.
2. Measure the temperature of the tip using an external thermometer with a thermocouple as sen-
sor. Make sure that the sensor of the external thermometer and the tip of the soldering iron can
keep sufficient contact. Wait for the display to reach the set temperature, then leave the tip on
the sensor for 60 s to measure the temperature correctly.
3. Press and hold the Set button to enter system configuration mode. Wait for the display to change
to [01], meaning "Current tool 01."
4. Press the Set button again to enter the digital offset function. The display shows a number
preceded by an "A." This means that the digital offset of the system is now being adjusted. A
display such as "A000" indicates that the digital setting is currently set to neutral.
5. Press the Up/Down buttons to change the digital offset. A number below zero indicates a down-
ward adjustment, a number above zero indicates an upward adjustment.
6. Adjust the value until the reading from the external temperature sensor and the set temperature
are the same.