Download Print this page

LE CACHE CellarPro 1800QTL-ECX Owner's Manual page 31

Advertisement

 The Cooling Unit Is Dripping
The cooling unit is designed to remove excess moisture from inside the cellar, which
collects in the drip pan of the cooling unit.
Excess moisture can occur when the cooling unit runs constantly, when the Minimum
Set Point is too low and/or when the cellar doesn't have a good seal from the outside
environment. To eliminate overflow in the drip pan, do the following:
1. Raise the Minimum Set Point of the cooling unit to 58 degrees or above.
2. Make sure the cellar has good seals, especially at the door(s), and repair any
leaks immediately.
3. If the unit is ducted at the front, make sure the ducting is tight against the face
of the cooling unit and well-sealed.
4. Make sure that the cooling unit is tilted slightly to the rear
5. If your wine cooling unit came with a condensate fitting and drain line, make
sure you properly setup the condensate trap (see Section II above).
If the cooling unit continues to drip, contact us at 877.726.8496 for further assistance.
 The LA2 Alarm has been triggered
The cooling unit is designed to measure the temperature of the condenser coils and,
if the temperature drops below a certain point, the LA2 alarm will display on the control
panel.
If you are getting an LA2 alarm, please contact us at 877.726.8496 for further
assistance.
30
v3.21

Advertisement

loading

Related Products for LE CACHE CellarPro 1800QTL-ECX