Power On/Off Button
Up and Down Buttons
Set Button
Press "Power On/Off" to turn the unit on and off
When the "Compressor On" indicator light is on, the
Compressor is running. When the "Fan On" indicator light
is on, the Fan is running
To view the "High Temp" recorded by the cooling unit, press
the "Up" button once.
To view the "Low Temp" recorded by the cooling unit, press
the "Down" button once
To reset the "High Temp" or "Low Temp", press the "Set"
button for three seconds while "Hi" or "Lo" is displayed.
"RST" will blink three times to indicate confirmation.
The cooling unit is factory preset with a Minimum Set Point
of 58°F and a Temperature Differential of 4°F. This
means that the cooling unit will turn on when the display
rises above 62°F (58°F + 4°F), and turn off when the
display falls below 58°F. In this example, the average
temperature inside the cellar will be 60°F.
To view the Minimum Set Point, press the "Set" button for
one second.
To change the Minimum Set Point,
1. Press the "Set" button for three seconds until "°F" blinks
2. Press the "Up" or "Down" button
3. Press the "Set" button to confirm
The "Set" temperature will blink three times to indicate
confirmation.
The recommended Minimum Set Point range is 53 - 60°F.
To change the Temperature Differential, see "Advanced
Operation" later in this chapter.
20
v3.21