The cooling unit has both an audible notification and a visual alarm indicator (shown
in "red" on the control panel) that are activated when an alarm is triggered. Please
note: the HA and LA alarms are disabled during the first 23 hours of operation after
the cooling unit is plugged in and/or turned on.
The control panel also will flash a code for each alarm, as follows:
Alarm Code
P1, P3
HA
HA2
LA
LA2
Alarms
What it means
Probe Failure
The temperature
inside the cellar is too
warm (above 70°F for
more than 1 hour)
The condenser
temperature is too
high (above 140°F)
The temperature
inside the cellar is too
cold (below 45°F)
The temperature at
the condenser coils
(outside the cabinet)
has dropped below the
alarm temperature
setting
26
What to do
Call CellarPro at 877.726.8496
Check seals;
Check if door was left open;
Lower the ambient temperatures
Check that the condenser fan (at
the rear of the cooling unit) is
operating;
Make sure that the filter (if used)
or coils are clean;
If the unit is ducted, make sure
that the auxiliary fan is operating;
Check for any blockages of the hot
air intake or exhaust
Then turn off the unit immediately
and call CellarPro at 877.726.8496
or email
info@cellarpro.com
Raise the ambient temperature;
Make sure the cold air discharge
has sufficient clearance for the air
to circulate
Raise the "Minimum Set Point"
Call CellarPro at 877.726.8496