A. Replacement Instructions
TOOLS NEEDED:
Phillips screwdriver
7/16" open end wrench or socket
Needlenose pliers
REQUIRED PARTS
Replacement Cooling Unit
Butyl Sealant Tape
REMOVAL OF OLD COOLING UNIT:
1. Unplug the cooling unit from the wall.
FROM THE TOP OF THE CELLAR
2. If your cellar comes with a grill(s), remove and discard the grill(s) on top of the
cellar. You do not need a grill with the CellarPro cooling unit.
3. Pull the power cord through the back of the cellar.
4. Note the location where sealant is applied to maintain an airtight seal inside
the cellar.
FROM THE FRONT OF THE CELLAR
5. Open cabinet door and remove all bottles from the top of the rack.
6. Place a heavy towel or blanket on top of the wine rack for protection.
7. IF YOU HAVE A LE CACHE MODEL 2400 WITH A CENTER POST: Remove the
center post by unscrewing the screws (two at the top and two at the bottom)
that attach the post to the wine cabinet.
8. Unplug the light from the cooling unit inside the cellar, and also unplug the cord
from the light fixture.
9. Remove the light fixture as follows:
- Slide the light left or right, and then unscrew and remove one of the two
mounting brackets that attach the light fixture to the ceiling of the cellar.
- Slide the light fixture off the second mounting bracket.