5753881-CTG-B-0420

PERFORMANCE DATA - 5 TON

CONDENSER-ONLY DATA (OUTDOOR UNIT)
SATURATED SUCTION
@ COMPRESSOR
MODEL
T (°F)
35
40
TW4B6021S
45
50
55
Notes:
1. For Outdoor Unit (Condenser) performance only. Data does not include the effects of air handler power or heat.
2. Performance based on 15°F subcooling and 15°F superheat at the Outdoor Unit base valves.
a. Increase capacity by 1% for each 2°F increase in subcooling.
b. Decrease capacity by 1% for each 2°F decrease in subcooling.
3. Maximum recommended condensing temperature is 140°F.
COOLING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
ID CFM
AIR TEMP.
ENTERING
ID DB (°F)
OUTDOOR UNIT (°F)
ID WB (°F)
55
65
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Green shaded cells are ACCA (TVA) conditions.
Blue shaded cells are AHRI conditions.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
110
55 °F
65 °F
P (PSIG)
MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW
107
61.4 2.72 58.5 2.99 55.5 3.32 52.5 3.70 49.3 4.16 46.0 4.70 42.3 5.30 38.4 6.00
118
67.5 2.73 64.3 3.00 61.1 3.33 57.8 3.71 54.4 4.17 50.7 4.70 46.9 5.31 42.7 6.00
130
73.9 2.74 70.5 3.01 67.1 3.34 63.5 3.72 59.8 4.17 55.8 4.71 51.7 5.32 47.2 5.99
142
80.8 2.75 77.0 3.03 73.3 3.35 69.5 3.73 65.6 4.17 61.3 4.72 56.8 5.33 52.1 5.99
156
88.2 2.76 84.1 3.04 80.0 3.37 75.8 3.76 71.6 4.19 67.1 4.73 62.3 5.34 57.3 5.99
TW4B6021S
CF60CXA1
1530
80
80
75
57
62
62
T.C.
55.3
58.7
59.6
S.C.
55.3
49.6
44.3
KW
3.10
3.14
3.13
T.C.
54.1
57.2
57.2
S.C.
54.1
49.2
42.6
KW
3.43
3.46
3.45
T.C.
52.9
55.6
54.7
S.C.
52.9
48.9
40.9
KW
3.76
3.78
3.77
T.C.
50.4
53.2
52.1
S.C.
50.4
47.4
39.6
KW
4.22
4.25
4.25
T.C.
47.9
50.8
49.6
S.C.
47.9
46.0
38.3
KW
4.69
4.71
4.72
T.C.
46.0
47.7
46.1
S.C.
46.0
44.5
36.4
KW
5.49
5.51
5.51
T.C.
44.1
44.7
42.8
S.C.
44.1
43.0
34.6
KW
6.26
6.29
6.28
T.C.
42.3
41.8
39.4
S.C.
42.3
41.6
32.7
KW
7.03
7.07
7.05
Outdoor Ambient Temperature
75 °F
85 °F
1730
80
80
80
80
75
67
72
57
62
62
63.7
66.8
57.5
59.6
60.2
43.0
33.6
57.5
52.4
46.2
3.15
3.17
3.19
3.22
3.21
62.0
65.7
56.1
58.2
58.0
41.9
33.0
56.1
52.1
44.9
3.47
3.48
3.51
3.54
3.53
60.3
64.7
54.6
56.7
55.9
40.9
32.5
54.6
51.7
43.6
3.78
3.78
3.84
3.86
3.85
57.9
62.4
52.1
54.2
53.4
39.9
31.5
52.1
50.2
42.3
4.24
4.23
4.30
4.32
4.31
55.4
60.2
49.5
51.6
50.9
38.9
30.5
49.5
48.6
41.0
4.70
4.67
4.75
4.78
4.78
52.4
57.0
47.5
48.6
47.5
37.6
29.1
47.5
46.9
39.0
5.47
5.41
5.52
5.56
5.57
49.5
53.8
45.5
45.7
44.1
36.3
27.7
45.5
45.3
37.1
6.22
6.13
6.27
6.32
6.34
46.5
50.7
43.6
42.8
40.7
35.0
26.4
43.6
42.8
35.2
6.96
6.84
7.02
7.08
7.10
95 °F
105 °F
115 °F
1930
80
80
80
80
75
67
72
57
62
62
64.3
67.1
59.7
60.5
60.7
44.3
34.5
59.7
55.2
48.1
3.24
3.25
3.27
3.30
3.29
62.9
66.4
58.0
59.1
58.9
43.7
34.1
58.0
54.9
47.2
3.55
3.56
3.59
3.62
3.61
61.5
65.7
56.4
57.8
57.1
43.2
33.7
56.4
54.6
46.3
3.86
3.86
3.91
3.93
3.92
58.7
63.3
53.7
55.1
54.7
42.1
32.6
53.7
52.9
45.0
4.31
4.30
4.37
4.39
4.38
56.0
60.8
51.1
52.5
52.3
41.0
31.6
51.1
51.2
43.7
4.77
4.75
4.82
4.84
4.84
53.0
57.4
49.0
49.6
48.8
39.7
30.2
49.0
49.3
41.7
5.53
5.48
5.56
5.61
5.63
50.1
54.0
46.9
46.7
45.4
38.4
28.9
46.9
46.7
39.7
6.26
6.20
6.28
6.36
6.39
47.2
50.7
44.9
43.9
42.0
37.1
27.5
44.9
43.9
37.8
7.00
6.92
7.00
7.10
7.15
Johnson Controls Ducted Systems
125 °F
80
80
67
72
65.0
67.5
45.7
35.4
3.32
3.33
63.8
67.1
45.5
35.1
3.63
3.64
62.6
66.8
45.4
34.8
3.94
3.94
59.6
64.1
44.2
33.8
4.39
4.38
56.6
61.4
43.1
32.7
4.83
4.82
53.6
57.8
41.8
31.4
5.58
5.56
50.7
54.2
40.5
30.0
6.31
6.28
47.8
50.7
39.3
28.7
7.04
7.00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents