Physical And Electrical Data; Dimensions - Coleman LX Series Technical Manual

Split system air conditioners 14 seer - r-410a - 1 phase 1.5 thru 5 nominal tons
Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

PHYSICAL AND ELECTRICAL DATA

MODEL
Unit Supply Voltage
1
Normal Voltage Range
Minimum Circuit Ampacity
Max. Overcurrent Device Amps
Min. Overcurrent Device Amps
Compressor Type
Rated Load
Compressor
Amps
Locked Rotor
Crankcase Heater
Factory External Discharge Muffler
HS Kit Required with TXV
HS Kit Part Number (S1-2SA067*****)
Fan Diameter Inches
Rated HP
Rated Load Amps
Fan Motor
Nominal RPM
Nominal CFM
Face Area Sq. Ft.
Coil
Rows Deep
Fins / Inch
Liquid Line Set OD (Field Installed)
Vapor Line Set OD (Field Installed)
6
Unit Charge (Lbs. - Oz.)
Charge Per Foot, Oz.
Operating Weight Lbs.
1. Rated in accordance with AHRI Standard 110-2012, utilization range "A".
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. Use S1-2SA067***** series kit. See Hard Start Kit Accessory Installation Manual.
5. For applications with non-standard vapor line sizes, see the "Applications & Accessories" section of this Technical Guide.
6. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract
the amount of refrigerant, using the difference in actual lineset length (not equivalent length) multiplied by the per foot value.
Johnson Controls Ducted Systems
TW4B1821S
TW4B2422S
11.8
14.8
2
20
3
15
Scroll
Scroll
9.0
11.2
56.3
60.8
No
No
No
No
No
No
4
10106
21806
18
1/12
1/8
0.64
0.8
1000
1075
1900
1950
12.37
12.21
1
23
3/8
3/8
5
3/4
3/4
3-6
3 - 12
0.62
0.62
130
135
TW4B3022S
TW4B3622S
208-230V, 1 60Hz
187 to 252
18.4
19.62
25
30
15
20
Scroll
Scroll
14.1
14.7
73.0
75.0
No
No
No
10106
10106
22
22
1/8
0.8
1075
2850
3275
12.21
17.37
1
1
23
23
3/8
3/4
3 - 14
0.62
0.62
140

DIMENSIONS

Unit
Model
TW4B1821S
TW4B2422S
TW4B3022S
TW4B3622S
TW4B4221S
TW4B4821S
TW4B6021S
‡ Adapter fitting must be field installed for the required 1-1/8" line set.
All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of base pan to top of fan guard.
Overall length and width include screw heads.
TW4B4221S
TW4B4821S
22.1
30
35
20
25
Scroll
Scroll
16.6
109.0
130.0
No
No
No
No
No
No
10106
10106
22
24
1/4
1/4
1.3
1.3
850
850
3500
18.74
18.74
1
1
23
23
3/8
3/8
3/4
7/8
4-4
4-15
4 - 15
0.67
160
200
Dimensions
Refrigerant Connection
(Inches)
A
B
C
33-1/4
24
24
26-3/4
29-1/4
29-1/4
26-3/4
29-1/4
29-1/4
36-1/4
29-1/4
29-1/4
33-1/4
35-1/4
31-3/4
33-1/4
35-1/4
31-3/4
36-1/4
38
34-1/4
5753881-CTG-B-0420
TW4B6021S
25.7
31.7
45
50
30
35
Scroll
19.5
24.3
144.2
No
No
No
No
No
No
10106
24
26
1/4
1/4
1.3
1.3
850
850
3500
4300
23.40
1
1
23
23
3/8
3/8
7/8
1-1/8
5 - 12
0.67
0.75
200
205
Service Valve Size
Liquid
Vapor
3/4
3/8
7/8
7/8
3