Electric Tilting Skillets
Maintenance
Contact the factory, the factory representative or a local service company to perform maintenance and repairs.
The tilting braising pan and its parts are hot. Use care when operating, cleaning and servicing the tilting braising pan.
Disconnect electrical power supply and place a tag at the disconnect switch
to indicate that you are working on the circuit before performing any maintenance.
Periodic Maintenance
1. Grease pivot bearings via lubricating nipple as required. Use Petro-Canada type 0G-2 or equivalent.
2. Check that screws in element terminals are not loose. Loose connections may cause arcing and burn off connection
causing element failure.
Troubleshooting
Unit Will Not Operate
1. Power supply not "ON".
2. Pan not in down position.
3. Defective thermostat or elements.
Pan Difficult to Operate
1. Unit not level.
2. Thrust bearings worn out.
3. Dirt in bearings causing it to bind.
4. Shaft bent.