Download Print this page
Annovi Reverberi AR 20 LFP Instruction Manual

Annovi Reverberi AR 20 LFP Instruction Manual

Semi-hydraulic three-diaphragm pump
Hide thumbs Also See for AR 20 LFP:

Advertisement

Quick Links

140° F - Max Water Temp
1" - Suction
3/8" HB - Outlet
AR20LFP - 1450
m
odeL
AR20LFP
AR25LFP - 1450
m
odeL
AR25LFP
d
iAPHRAgm
m
d
odeL
eScRiPTion
AR46561
BlueFlex
INSTRUCTION MANUAL
- S
-H
RPm
emi
m
gPm
m
Ax
Ax
20
5.3
- S
-H
RPm
emi
m
gPm
m
Ax
Ax
24.3
6.4
K
V
K
iTS
ALVe
m
odeL
AR46564 Valves
TM
AR46565 Valves
AR 20 LFP
AR 25 LFP
T
-d
ydRAuLic
HRee
L/m
m
PSi
in
Ax
290
T
-d
ydRAuLic
HRee
L/m
m
PSi
in
Ax
290
o
iTS
iL
d
m
eScRiPTion
odeL
AR64532D
(bp)
AR64532D-C Case (6)Oil
(LFP)
P
iAPHRAgm
umP
m
B
HP P
Ax
AR
oweR
20
1.0
P
iAPHRAgm
umP
m
B
HP P
Ax
AR
oweR
20
1.1
d
eScRiPTion
Oil
w
eigHT
L
.
BS
9.2
w
eigHT
L
.
BS
9.2

Advertisement

loading
Need help?

Need help?

Do you have a question about the AR 20 LFP and is the answer not in the manual?

Questions and answers

Summary of Contents for Annovi Reverberi AR 20 LFP

  • Page 1 AR 20 LFP AR 25 LFP 140° F - Max Water Temp 1” - Suction 3/8” HB - Outlet INSTRUCTION MANUAL AR20LFP - 1450 ydRAuLic HRee iAPHRAgm eigHT HP P odeL oweR AR20LFP AR25LFP - 1450 ydRAuLic HRee iAPHRAgm eigHT...
  • Page 2 AR20LFP AR25LFP Pump -SP-GCI Version Shown with Hydraulic Flange SAE A-A -GR-GCI Version AR20LFP-GCI-12VDC AR25LFP-GCI-12VDC Part Number AR55387 for Gas Engines with 3/4" Shaft AR20LFP-GCI-24VDC (Hydraulic Motor not included) AR25LFP-GCI-24VDC...
  • Page 3 CONTROL UNIT INSTRUCTIONS Red Pressure Adjustment Knob Bypass Hose Pressure/Bypass Barb Lever shown in Pressure Position Outlet Hose Barb 2 Places Remote Mount Inlet Hose Barb 1. When starting the pump, keep the control unit in the full bypass position until the pump has primed.
  • Page 4: Important Safety Information

    IMPORTANT SAFETY INFORMATION Intended uses The pump is designed and constructed for incorporation in plants and machinery (spraying machines for the protective treatment of agricultural crops and garden plants). All other uses constitute misuse unless ap- proved by the manufacturer's technical service The pump must be used in a manner appropriate to its technical data (see “Technical Data”), and must not be modified or improperly used.
  • Page 5 Installation diagram (guideline) The following is a simplified illustration of the typical installation layout and is purely a guideline. Control Unit by-pass Tank Agitation Control Unit Intake filter Pump Delivery line filter...
  • Page 6: Installation Instructions

    INSTALLATION INSTRUCTIONS General guidelines on water supply connection To operate correctly, the diaphragm pump must draw in liquids from containers at atmospheric pressure. Do not supply the pump with pressurised liquids. For continuous duty, the pump should not draw in water by gravity from containers with liquid level at heights above 3 m.
  • Page 7 Safety recommendations for handling and lifting Before starting the operations, organise the intended working area so that the materials can be lifted and handled in safety. Unloading, loading, handling and lifting operations must be carried out by skilled, authorised, specifi­ cally trained staff.
  • Page 8 Installation • The crankshaft may turn in either direction. • The water connection with the pump must be made using hoses of suitable diameter, in all case no less than that of the pump fittings, securing them to the fittings using good quality clamps. The intake hose must be coil-reinforced to prevent restrictions.
  • Page 9 Safety recommendations for use Before start-up, the operator must perform the necessary safety checks. In the event of leaks from the pressurized pipes, stop the pump at once and fix the leak. Do not operate the pump above the limits set by the manufacturer to increase its performance. Preliminary checks If the pump has a pressure accumulator, check its level of inflation, see "Checking the inflation pressure".
  • Page 10 Safety recommendations for maintenance Before doing any maintenance work, depressurise the water system and isolate the pump from all en- ergy sources. When the jobs are done, before restarting the pump, check that no tools, rags or other materials have been left close to moving parts or in hazardous zones.
  • Page 11 Table of lubricants The pump is delivered complete with high-performance 30 weight, non-detergent oil suitable for the intended ambient conditions (see "Environmental operating limits"). Inspecting the pump mounting Check that the pump's fixing screws have not become loose. If necessary, tighten them with the driving torque stated in the installation design. Inspecting the connections and pipes - Inspect the connections for leaks.
  • Page 12 Pump Storage It is important to comply with the recommendations for storage in the operator's manual of the machine into which the pump is incorporated. For the pump itself, at the end of pumping operations it is essential to flush out the pump by pumping clean water.
  • Page 13: Troubleshooting

    TROUBLESHOOTING The information provided is intended to provide guidance how to deal with malfunctions which may occur during use. Some of these procedures may be carried out by skilled staff, while others have to be performed at specialised service centres since they require the use of specific equipment as well as detailed knowledge of repair opera­ tions.
  • Page 14 TROUBLESHOOTING Remedy Problem Cause Oil seal on pump Replace the worn oil seal. shaft worn. Oil on pump body or base. Oil pressure inside pump too high. Restore correct oil level in tank. Pump using too much oil (oil flowing from delivery port) or oil Stop the pump at once.
  • Page 15 A.R. NORTH AMERICA A.R. NORTH AMERICA AR20LFP-GR-GCI / AR25LFP-GR-GCI 6 - 1 6 - 2 6 - 3 6 - 4 6 - 6 6 - 5 2021 AR North America...
  • Page 16 GR GCI AR20LFP-GR-GCI / AR25LFP-GR-GCI AR20LFP 33280 AR25LFP 33279 Code Description Note Code Description Note 3340011 Pump body 3120150 Ring 3340030 Manifold 1460490 Snap ring Øi 47 3340020 Head 393790 Washer 3340590 Retaining washer 2840891 O-ring Ø 14x2 Viton 3340221 Bolt M6x55 T44* SS 3202140 Plug...
  • Page 17 A.R. NORTH AMERICA A.R. NORTH AMERICA AR20LFP-SP-GCI / AR25LFP-SP-GCI 4 - 1 4 - 2 4 - 3 4 - 4 4 - 6 4 - 5 2021 AR North America...
  • Page 18 SP GCI AR20LFP-SP-GCI / AR25LFP-SP-GCI AR20LFP 33310 AR25LFP 33309 Code Description Note Code Description Note 3340011 Pump body 3340560 Shaft marked EC AR20 3340570 Shaft marked ED AR25 3340030 Manifold 3340020 Head 380230 Bearing 3120150 Ring 3340590 Retaining washer 3340221 Bolt M6x55 T44* SS 1460490 Snap ring...
  • Page 19 AR20LFP-SP-GCI & AR25LFP-SP-GCI Dimensions Ø 3/4" 9.2" 4.1" 4.3" Ø 0.33" 8.4" 4.8" 11.6" 0.79" 1.22" 2.05" 2.57" 2.95" 2.93" 5.89" 7.74"...