Summary of Contents for Annovi Reverberi AR45LFP-C
Page 1
AR 45 LFP AR45LFP-GR-GCI AR45LFP-C 140° F - Max Water Temp 140° F - Max Water Temp 1 1/4” - Suction 1 1/4” - Suction 1/2” - Hose Barb Outlet 1” - Outlet 3/4" - Bypass Hose Barb INSTRUCTION MANUAL...
Page 2
INSTALLATION INSTRUCTIONS Sight Glass Inlet Hose Barb Full Bypass Full Pressure Lever Position Lever Position Pressure Adjustment Knob Bypass Hose Press/Bypass Lever Barb shown in Pressure Position Outlet Hose Barb (2 places) Remote Mount Inlet Hose Barb SP Version C Version Straight 3/4”...
Page 3
CONTROL UNIT INSTRUCTIONS Red Pressure Adjustment Knob Bypass Hose Press/Bypass Barb Lever shown in Pressure Position Outlet Hose Barb 2 Places Remote Mount Inlet Hose Barb 1. When starting the pump, keep the control unit in the full bypass position until the pump has primed.
IMPORTANT SAFETY INFORMATION Intended uses The pump is designed and constructed for incorporation in plants and machinery (spraying machines for the protective treatment of agricultural crops and garden plants). All other uses constitute misuse unless ap- proved by the manufacturer's technical service The pump must be used in a manner appropriate to its technical data (see “Technical Data”), and must not be modified or improperly used.
Page 5
Installation diagram (guideline) The following is a simplified illustration of the typical installation layout and is purely a guideline. Control Unit by-pass Tank Agitation Control Unit Intake filter Pump Delivery line filter...
INSTALLATION INSTRUCTIONS General guidelines on water supply connection To operate correctly, the diaphragm pump must draw in liquids from containers at atmospheric pressure. Do not supply the pump with pressurised liquids. For continuous duty, the pump should not draw in water by gravity from containers with liquid level at heights above 3 m.
Page 7
Safety recommendations for handling and lifting Before starting the operations, organise the intended working area so that the materials can be lifted and handled in safety. Unloading, loading, handling and lifting operations must be carried out by skilled, authorised, specifi cally trained staff.
Installation • The crankshaft may turn in either direction. • The water connection with the pump must be made using hoses of suitable diameter, in all case no less than that of the pump fittings, securing them to the fittings using good quality clamps. The intake hose must be coil-reinforced to prevent restrictions.
Safety recommendations for use Before start-up, the operator must perform the necessary safety checks. In the event of leaks from the pressurized pipes, stop the pump at once and fix the leak. Do not operate the pump above the limits set by the manufacturer to increase its performance. Preliminary checks If the pump has a pressure accumulator, check its level of inflation, see "Checking the inflation pressure".
Page 10
Safety recommendations for maintenance Before doing any maintenance work, depressurise the water system and isolate the pump from all en- ergy sources. When the jobs are done, before restarting the pump, check that no tools, rags or other materials have been left close to moving parts or in hazardous zones.
Page 11
Table of lubricants The pump is delivered complete with high-performance 30 weight, non-detergent oil suitable for the intended ambient conditions (see "Environmental operating limits"). Inspecting the pump mounting Check that the pump's fixing screws have not become loose. If necessary, tighten them with the driving torque stated in the installation design. Inspecting the connections and pipes - Inspect the connections for leaks.
Page 12
Pump Storage It is important to comply with the recommendations for storage in the operator's manual of the machine into which the pump is incorporated. For the pump itself, at the end of pumping operations it is essential to flush out the pump by pumping clean water.
TROUBLESHOOTING The information provided is intended to provide guidance how to deal with malfunctions which may occur during use. Some of these procedures may be carried out by skilled staff, while others have to be performed at specialised service centres since they require the use of specific equipment as well as detailed knowledge of repair opera tions.
Page 14
TROUBLESHOOTING Remedy Problem Cause Oil seal on pump Replace the worn oil seal. shaft worn. Oil on pump body or base. Oil pressure inside pump too high. Restore correct oil level in tank. Pump using too much oil (oil flowing from delivery port) or oil Stop the pump at once.
Page 15
A.R. NORTH AMERICA A.R. NORTH AMERICA AR45LFP / AR 45 bp Warning! Fit with molybdenum disul de grease between plate and diaphragm. 8 - 1 8 - 2 8 - 3 8 - 4 8 - 5 2021 AR North America...
Page 17
A.R. NORTH AMERICA A.R. NORTH AMERICA AR45LFP GR - GCI Warning! Fit with molybdenum disul de grease between plate and diaphragm. 40 42 10 - 1 10 - 2 10 - 3 10 - 4 Gear Box AR31185 Suggested Oil Type 90W Gear Lube 14 10 - 5...
Page 18
GR-GCI AR 45LFP GR - GCI AR45LFP 31878 Code Description Note Code Description Note 621782 Bolt M8x40 SS T90* 3120690 Plug 3/8" G T15* 2840891 O-Ring Ø 14x2 Viton 720031 O-Ring Ø 22.22x2.62 Viton 1880460 O-Ring Ø 29x3 Viton 3120050 Manifold 750670 Ring nut 1-1/2"...
Page 19
A.R. NORTH AMERICA A.R. NORTH AMERICA AR45LFP GR Warning! Fit with molybdenum disul de grease between plate and diaphragm. 40 42 ∆ 12 - 1 12 - 2 12 - 3 12 - 4 Gear Box AR31185 Suggested Oil Type 90W Gear Lube 14 12 - 5 2021 AR North America...