Annovi Reverberi AR70BP Instruction Manual

Hide thumbs Also See for AR70BP:

Advertisement

Quick Links

140° F - Max Water Temp
1-1/4" - Suction
1" - Outlet
AR70BP - 550
m
odeL
AR70BP-C
AR70BP-SP
AR70BP-GR3/4
d
K
iAPHRAgm
iTS
m
d
odeL
eScRiPTion
AR43243
BlueFlex
AR43241
Desmopan
AR43240
NBR
INSTRUCTION MANUAL
- S
-H
RPm
emi
ydRAuLic
m
gPm
m
Ax
Ax
19.6
74.1
19.6
74.1
19.6
74.1
V
K
ALVe
iTS
m
d
odeL
eScRiPTion
AR2364
Valves
T
-d
wo
iAPHRAgm
L/m
m
PSi
in
Ax
290
290
290
o-R
K
ing
iTS
m
d
odeL
eScRiPTion
AR2365
O-Rings
AR 70 bp
P
umP
m
B
HP P
Ax
AR
oweR
20
3.4
20
3.4
20
3.4
o
iL
m
odeL
AR64532D
AR64532D-C Case (6)Oil
w
eigHT
L
.
BS
26
26
31
d
eScRiPTion
Oil

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR70BP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Annovi Reverberi AR70BP

  • Page 1 AR 70 bp 140° F - Max Water Temp 1-1/4” - Suction 1” - Outlet INSTRUCTION MANUAL AR70BP - 550 ydRAuLic iAPHRAgm eigHT HP P odeL oweR AR70BP-C 19.6 74.1 AR70BP-SP 19.6 74.1 AR70BP-GR3/4 19.6 74.1 iAPHRAgm ALVe odeL odeL...
  • Page 2 Application Kits Low Pressure AR31058 AR43329 Shaft Kit AR43392: 1 3/8” Male Spline Shaft Pulley Kit AR31058 Pulley 2A 11” Diameter 1" ³⁄₈ universal shaft For AR45, AR80 86,5 For Models: AR70, AR115 & AR135 Hydraulic Motor Flange Kit AR55371 AR55371 AR1514 $281.40...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION Intended uses The pump is designed and constructed for incorporation in plants and machinery (spraying machines for the protective treatment of agricultural crops and garden plants). All other uses constitute misuse unless ap- proved by the manufacturer's technical service The pump must be used in a manner appropriate to its technical data (see “Technical Data”), and must not be modified or improperly used.
  • Page 4 Installation diagram (guideline) The following is a simplified illustration of the typical installation layout and is purely a guideline. Control Unit by-pass Tank Agitation Control Unit Intake filter Pump Delivery line filter...
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS General guidelines on water supply connection To operate correctly, the diaphragm pump must draw in liquids from containers at atmospheric pressure. Do not supply the pump with pressurised liquids. For continuous duty, the pump should not draw in water by gravity from containers with liquid level at heights above 3 m.
  • Page 6 Safety recommendations for handling and lifting Before starting the operations, organise the intended working area so that the materials can be lifted and handled in safety. Unloading, loading, handling and lifting operations must be carried out by skilled, authorised, specifi­ cally trained staff.
  • Page 7: Installation

    Installation • The crankshaft may turn in either direction. • The water connection with the pump must be made using hoses of suitable diameter, in all case no less than that of the pump fittings, securing them to the fittings using good quality clamps. The intake hose must be coil-reinforced to prevent restrictions.
  • Page 8 Safety recommendations for use Before start-up, the operator must perform the necessary safety checks. In the event of leaks from the pressurized pipes, stop the pump at once and fix the leak. Do not operate the pump above the limits set by the manufacturer to increase its performance. Preliminary checks If the pump has a pressure accumulator, check its level of inflation, see "Checking the inflation pressure".
  • Page 9 Safety recommendations for maintenance Before doing any maintenance work, depressurise the water system and isolate the pump from all en- ergy sources. When the jobs are done, before restarting the pump, check that no tools, rags or other materials have been left close to moving parts or in hazardous zones.
  • Page 10 Table of lubricants The pump is delivered complete with high-performance 30 weight, non-detergent oil suitable for the intended ambient conditions (see "Environmental operating limits"). Inspecting the pump mounting Check that the pump's fixing screws have not become loose. If necessary, tighten them with the driving torque stated in the installation design. Inspecting the connections and pipes - Inspect the connections for leaks.
  • Page 11 Pump Storage It is important to comply with the recommendations for storage in the operator's manual of the machine into which the pump is incorporated. For the pump itself, at the end of pumping operations it is essential to flush out the pump by pumping clean water.
  • Page 12: Troubleshooting

    TROUBLESHOOTING The information provided is intended to provide guidance how to deal with malfunctions which may occur during use. Some of these procedures may be carried out by skilled staff, while others have to be performed at specialised service centres since they require the use of specific equipment as well as detailed knowledge of repair opera­ tions.
  • Page 13 TROUBLESHOOTING Remedy Problem Cause Oil seal on pump Replace the worn oil seal. shaft worn. Oil on pump body or base. Oil pressure inside pump too high. Restore correct oil level in tank. Pump using too much oil (oil flowing from delivery port) or oil Stop the pump at once.
  • Page 14 A.R. NORTH AMERICA A.R. NORTH AMERICA AR 70 bp Optional 16 - 1 16 - 2 Warning! Fit with molybdenum disul de grease between plate and diaphragm 16 - 3 16 - 4 16 - 5 2021 AR North America...
  • Page 15 GR3/4 AR 70 bp AR70bp 33156 31698 31700 Code Description Note Code Description Note 550170 Shaft marked AL 550011 Pump body 320621 Washer Geomet 550101 Head 659209 Diaphragm 550102 Head 550280 Bushing 550150 Fitting 550140 Cylinder trolling piston 550180 Semi air chamber...
  • Page 16 961790 Ring circlip Øi 68 961800 Oil seal 881090 Key 550175 Shaft marked AN 1 AR70bp- AR115bp* 580430 Shaft marked AX 1 AR135bp* For gas engine with 3/4” shaft, flange SAE J609a *Torque: in/lbs +/- 10% 2021 AR North America...

This manual is also suitable for:

Ar70bp-cAr70bp-spAr70bp-gr3/4

Table of Contents