EN 60335-2-29, EN 55014-1-2, EN 61000-3-2, EN 61000-3-3, EN60335-1 MASSIMO CICERI MILANO ( Member of the board) tam e o c a e a t o e b BETA UTENSILI s all mme atel al ate t s stateme t.
INSTRUCTIONS FOR USE INSTRUCTION MANUAL Model: 12V – Charge 5Ah-500Ah CONTROL PANEL Signalling LEDs There are 15 LEDs on the front panel having the following functions: • 4 battery status LEDs, indicating: - Full : battery is charged and is in charge maintenance status - Charging : battery charging - Fault : battery is damaged - Reverse : polarity reversal...
Page 5
INSTRUCTIONS FOR USE BATTERY CHARGER FEATURES AND OPERATING MODES A) Operating modes F nction C arge Battery charging mode. There are 7 charging steps, as described below: • STEP 1: Analysis 1. If the battery output is less than 6.5V, the unit proceeds with the next step. Outputs below 6.5V will cause the device to revert to stand-by.
Page 6
INSTRUCTIONS FOR USE B) Flas s pply and c arging mode Amperage Preset supply current bands: A supply current set to 5A Flas A supply current set to 15A Flas A supply current set to 30A Flas A supply current set to 50A Flas Preset charging bands to select the connected battery (output current adjusted automatically) A Supports batteries from 5Ah to 50Ah.
Page 7
INSTRUCTIONS FOR USE DISPLAY CAUSE SOLUTION INDICATION Internal overheating of battery Remove any objects that could be covering the ventilation area charger. Battery charger overload. of the battery charger or move it to a cooler area. ait for the battery charger to start again automatically. Voltage error.
INSTRUCTIONS FOR USE BATTERY CHARGING C arging batteries connected to t e ve icle 1. Before starting to charge the battery, make sure the power supply lead is not plugged into the mains supply. 2. Locate the vehicle’s earthing point, which is normally connected to the negative battery terminal. 3.
INSTRUCTIONS FOR USE • Volt / Batt ey (see section C - “Flash” supply voltages and supported batteries: “Volt / Batt.”) Depending on the supply voltage required to support the battery voltage during reprogramming operations (ONLY FLASH MODE), you can select three different supply voltages: .
Need help?