Installation

Clearances to Combustibles

Confirm required clearances to combustibles (Combustibles include wood, drywall, etc...)
5"
Horizontal installation
Back walls to Stove rear corners: 5" (13cm)
Back wall to Stove back: 2" (5cm)
Side wall to Stove: 7" (18cm)
5"
2"
5"
Vertical installation
Back walls to Stove rear corners: 5" (13cm)
Back wall to pellet pipe: 2" (5cm)
Side wall to Stove: 7" (18cm)
Notice: When interior vent is installed vertically, the clearance to the back wall is determined by the vent
size used. Install vent at clearance specified by the vent manufacturer. Take into consideration any upward
turning elbows or tees.
CAUTION!
Take appropriate precautions to locate utilities within the wall and avoid contact.
5"
10
2"
7"
2"
7"
comfortbilt.net